NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (STICK)

TROUBLESHOOTING & REPAIR
All manuals and user guides at all-guides.com
MAX CONTROL POT - HIGH IDLE - NO LOAD
50V
This is the typical DC open circuit out-
put voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 5 milliseconds in time.
NOTE: Scope probes are connected
at weld output terminals.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
RANGER 305D
CH1
0 volts
5ms