Honeywell Maxon VALUPAK-II Operating Instructions Manual page 7

Low temperature burners
Table of Contents

Advertisement

10.2 VP-II burner specification, 50 Hz
Capacity and selection data in kW, 50 Hz operation. Gross heating value = 10.9 kWh/m
All figures are for balanced - 0 mbar - duct pressure
Burner
Blower
Maximum heat release
5)
[kW] (HHV)
Minimum heat release [kW] (HHV)
Pilot capacity (typical) [kW] (HHV)
Turndown
1)
Q gas
[m
/h(st)]
max.
3
Q gas
[m
/h(st)]
min.
3
Q air
[m
/h(st)]
max.
3
Q air
[m
/h(st)]
min.
3
Excess air at max. (n)
Excess air at min. (n)
Flame length at max. capacity (open air)
Δp gas max. at burner inlet [mbar]
Δp gas max. at burner test connection (typical) [mbar]
Δp gas max.at pilot connection [mbar]
Air diff. pressure at test connection
at maximum heat release [mbar]
at minimum heat release [mbar]
CO turn down, typical (ref. 100 mg/m
Torque gas-air linkage [Nm]
Lp at 1 m blower, max. capacity
Lw at max. capacity
7)
[dB(A)]
Weight [kg]
Blower motor [kW]
Burner
Blower
Maximum heat release
5)
[kW] (HHV)
Minimum heat release [kW] (HHV)
Pilot capacity (typical) [kW] (HHV)
Turndown
1)
Q gas
[m
/h(st)]
max.
3
Q gas
[m
/h(st)]
min.
3
Q air
[m
/h(st)]
max.
3
Q air
[m
/h(st)]
min.
3
Excess air at max. (n)
Excess air at min. (n)
Flame length at max. capacity (open air)
Δp gas max. at burner inlet [mbar]
Δp gas max. at burner test connection (typical) [mbar]
Δp gas max.at pilot connection [mbar]
Air diff. pressure at test connection
at maximum heat release [mbar]
at minimum heat release [mbar]
CO turn down, typical (ref. 100 mg/m
Torque gas-air linkage [Nm]
Lp at 1 m blower, max. capacity
Lw at max. capacity
[dB(A)]
7)
Weight [kg]
Capacity blower motor [kW]
1) Air pressure switches should be selected to have a setpoint ranging from 2-10 mbar.
2) Single phase blower motor available.
3) The EB Valupak II requires an external blower with flat characteristics.
4) As an alternative blower U/HC142 (0,18 kW) can be used. Performance is the same as with UMI300 blower.
5) Use of the standard round air inlet filter will cause a ± 15% capacity reduction. UMI blowers are not suited for filters.
6) When firing in open air. Firing in a cross flow shortens the flame.
7) Sound data refers to open firing burner in free field of conditions, at maximum capacity.
1)
UHC102
6)
[m]
3
at 17% O
)
2
7)
[dB(A)]
UMI300
290
6
23
48:1
28.1
0.6
323
55
1.2
9.9
6)
[m]
1.3
10.8
5
17
3.7
0.2
3
at 17% O
)
30:1
2
0.3
[dB(A)]
86
7)
94
29.7
0.25
3
(st), d = 0,6
VP-II-60
2)
UHC122
UMI300
40
60
80
2
2
3
NA
20:1
30:1
27:1
3.7
5.5
7.3
0,18
0,18
0,28
48
64
98
NA
1.17
1.17
1.17
NA
up to 0.4 (after sleeve)
6.7
11.5
24
5.4
9
18
NA
2
3,3
6,3
0.4
0.5
0.6
NA
NA
NA
NA
13
14.2
18
0.09
0.09
0.25
VP-II-300
2)
eB
3)
4)
UMI390
UHC182
20 mbar
360
633
10
12.6
29
51
36:1
50:1
34.8
61.3
1.0
1.2
401
706
72
117
1.2
1.2
7.8
10
1.5
2.3
15.2
46.7
7.7
23.5
27
83
6.5
18.5
0.2
-
25:1
17:1
0.3
0.5
92
-
98
-
31.5
20.5
0.55
0.75
EN-7
VP-II-150
2)
UHC122
UMI300
4)
185
225
6
6
26
32
31:1
38:1
17.9
21.8
0,6
0,6
206
251
53
67
1.2
1.2
9.5
12
1
1
14.2
20.8
9.8
14.6
18
27
2.6
4,4
0.15
0.25
30:1
22:1
0.3
0.3
86
86
94
94
20
24.2
0.09
0.25
VP-II-600
VP-II-900
2)
UHC202 UHC182
558
634
880
15
15
15
37
42
41
37:1
42:1
59:1
54.0
61.4
85.2
1.5
1.5
1.5
622
707
981
144
174
205
1.2
1.2
1.2
10.3
12.5
14.7
1.6
1.7
2
16.2
20.8
23.9
10.2
12.9
5.2
17.6
23
35
6.9
9.7
6.6
0.45
0.6
0.4
12:1
10:1
20:1
1
1
1
96
99
96
102
105
102
47.6
55
70.4
1.1
1.5
1.1
eB
3)
20 mbar
417
9
59
44:1
40.4
0,9
465
116
1.2
13.2
1.8
71.5
50.3
93
15.2
-
4:1
0.5
-
-
15
0.55
2)
UHC202
1060
15
49
71:1
102.6
1.5
1133
230
1.15
16.5
2.2
33.9
7.4
51
8.4
0.5
15:1
1
99
105
78
1.5