Removing Fan Motor - Miller Auto-Line Invision 352 MPa Technical Manual

Hide thumbs Also See for Auto-Line Invision 352 MPa:
Table of Contents

Advertisement

9-3. Removing Fan Motor

1
4
Tools Needed:
1/2, 9/16 in.
5/16 in.
TM-246193 Page 66
2
3
!
Significant DC voltage can
remain on capacitors after
unit is Off. Always check
capacitors
according
Section 8-3 to be sure they
have
discharged
before
working on unit.
.
Drawing is representative and
may not reflect actual unit.
1
Mounting Unit Foot
2
Base
3
Fan Motor
4
Louver
Remove wrapper from unit.
Place unit upside down on secure
work area as shown.
Remove mounting unit feet.
Lift off base.
Remove louver from front panel as-
sembly.
Remove bolts (2) securing fan as-
sembly.
Disconnect fan motor plug and re-
move fan from unit.
Reverse steps to replace fan motor
in unit.
805299-A