Remote 14 Receptacle Information; Optional 115 Volts Ac Duplex Receptacle And Supplementary Protectors - Miller Auto-Line Invision 352 MPa Technical Manual

Hide thumbs Also See for Auto-Line Invision 352 MPa:
Table of Contents

Advertisement

4-4. Remote 14 Receptacle Information

A
J
K
I
B
C L N
H
M
D
G
F
E
*The remaining sockets are not used.

4-5. Optional 115 Volts AC Duplex Receptacle And Supplementary Protectors

Invision 352 MPa
24 VOLTS AC
REMOTE
OUTPUT
CONTROL
A/V
AMPERAGE
VOLTAGE
GND
1
Socket*
Socket Information
A
24 volts AC. Protected by supplementary protect-
or CB2.
B
Contact closure to A completes 24 volts AC
contactor control circuit.
C
Output to remote control; 0 to +10 volts DC, +10
volts DC in MIG mode.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from
remote control.
L
Wirefeed speed command, 0 to +10 volts DC out-
put signal from wire feeder.
M
CC/CV select 0 to +10 volts DC.
N
Wirefeed speed common.
F
Current feedback; +1 volt DC per 100 amperes.
H
Voltage feedback; +1 volt DC per 10 output recep-
tacle volts.
G
Circuit common for 24 volts AC circuits.
K
Chassis common.
1
115 V 10 Amp AC Receptacle
2
Supplementary Protector CB1
3
Supplementary Protector CB2
CB1 protects duplex receptacle
from overload.
CB2 protects 24 volts AC portion of
Remote
overload.
Press button to reset supplement-
ary protector.
2
3
14
receptacle
from
803691-E
TM-246193 Page 11

Advertisement

Table of Contents
loading

Table of Contents