Introduction ........................... 3 Safety Information ........................4 1.0 Installation ..........................8 1.1 Composition of the MagPurix 24 EVO system ..............8 1.2 Contents of Reagent Kits ....................9 1.3 Operating Environment / Condition ................. 9 1.4 Unpack the MagPurix 24 EVO system ................11 1.5 Overall View ........................
Introduction Thank you for purchasing the MagPurix 24 EVO which is a fully automated, standalone robot that can purify nucleic acids within 30-45 minutes. With advanced magnetic bead separation technology, it enables you to obtain high-quality extraction results. Moreover, the most user- friendly interface makes users free from troublesome parameter settings and maintenance.
This symbol shows this instrument is an “In vitro diagnostic”-certified medical device. For your safety and that of others, follow the guidelines provided in the following pages concerning the use of the MagPurix 24 EVO system. www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 5
Do not use the MagPurix 24 EVO system with a damaged power plug or a loose socket. If there is dust on the prongs of the power plug or on the plug socket, remove it with a dry cloth.
Page 6
Extraction should be performed in an appropriate laboratory or workplace. Note: The kits are not supplied with the MagPurix 24 EVO system. Select the desired kit(s) and order it (them) separately. www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 7
Zinexts Life Science Corp. www.zinexts.com 16F., No. 93, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221416, Taiwan Tel: +886 2 2246 3579 Fax: +886 2 2243 8570 www.zinexts.com MagPurix 24 EVO Instruction Manual...
Please make sure all the components are free from damages as soon as you get the system. If any damage is found, please contact your local representative for instant support. Note: Zinexts’ global warranty does not cover damages from transportation or improper operation. www.zinexts.com MagPurix 24 EVO Instruction Manual...
The contents of reagent kits will vary. Refer to the handbook of kits enclosed in reagent box for details. 1.3 Operating Environment / Condition Use the MagPurix 24 EVO system in a location that meets the following conditions: www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 10
The MagPurix 24 EVO system must be place at a minimum distance of 5-10 cm from all sidewalls to allow good air circulation. The space for the allocation of the MagPurix 24 EVO system must remain 5-10 cm from instrument to sidewalls.
Warning: Do not use the MagPurix 24 EVO system in a location where it is wet or can be splashed with water. It may cause device failure, fire, or electric shock. When relocating the MagPurix 24 EVO system, disconnect the plug from the outlet first.
Improper MagPurix 24 EVO system movement handling will lead to instrument damages. For correct and safe use of the MagPurix 24 EVO, install the device in a location close to the electrical outlet and that has enough space for installation and main switch operation .
Page 13
UV Lamp Camera Recorder Operation Area There is a total of 24strips (from left to right) Inside view Piston Reagent kit holder Heating module Tip holder plate M module Holder lid Sample rack www.zinexts.com MagPurix 24 EVO Instruction Manual...
“Service” password to lock access to end user to certain “service” options) (Please refer to System Status for the operate information) iii. Set up the local time. (Please refer to System Status for operating information) www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 15
System will start to do the initialization and device will release transportation fixing parts automatically. Dashcam time adjustment Dashcam time adjustment is suggested for the first use. Fallow the steps below to set the dashcam time: www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 16
Step 4, find each button from left side of camera and follow below steps. Step 5, the dashcam will automatically Step 6, long press “M” button access to start recording after turn off sensor. menu. Press “OK “button to pause. www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 17
As an end user, please log in with User ID “Admin” (as end user/top authority in the laboratory) without password. You can set your Top authority “Admin” password to lock access to user to certain “Admin” options www.zinexts.com MagPurix 24 EVO Instruction Manual...
Once logged in, you will able to set up at least 10 other users with their own password. Important: Keep the shipping box and fixing block materials. They will be needed again when transporting the MagPurix 24 EVO system. 2.2 Touch Panel and User Interface Function Bar Homepage Status Bar 2.3 Preparation...
Press button then system will going to check the position automatically. (Please refer to System Status for the operate information) 2.5 Extraction (1) Plastic consumable set up: www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 20
(push down each wells) Close the tip holder lids Insert Piercing Pins Insert Filter tips Stick the barcode label Insert Sample Tube Insert Elution Tube Load the sample(s) (On Sample Rack) (On Sample Rack) (To Sample Tube) www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 21
Make sure that Cartridges are inserted into the Cartridge Tray tightly. You can load 1-24 strips on the tray depending on the number of samples you intend to process. (2) Start Program: (Please refer to System Status for operating information) www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 22
Select the desired targets from homepage Select the Protocol then Press “NEXT” Select Sample and Elution Volume then Select the Sample number then Press Press “NEXT” “NEXT” Edit the Sample ID then Press “NEXT” www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 23
Edit the Elution ID then Press “NEXT” Scan Reagent Cartridge Barcode then Press “NEXT” Zinexts do not guarantee with expired kit performance. “Admin” &“Service” ID have to take responsibility for kit usage status. System display a consumable Checklist, Tick corresponding boxes then Press “NEXT”. Note: The system will not allow user to go forward if not all consumable boxes are ticked.
(Please refer to System Status for operating information) (2) Put back the Fixing block at the Position of cartridge holder. 3.0 Cleaning & Maintaining the MagPurix 24 EVO Once the sample or the buffer splash, stop to clean as following information.
Page 25
3.2 Cleaning of Piston (1) Enter to “setting” and select “System” (2) Clean piston (Red Square) by kimwipes with select ”Piston” 75% ETOH and change new piston if there is significant impurity stain, salt crystal. www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 26
3.2 Routine and Preventive Maintenance Two types of maintenance are to be performed on the MagPurix 24 EVO system instrument as listed in the table. For details on each type of maintenance, see below: Schedule Maintenance Type Performed by Routine Cleaning of sample Tray, M ...
Page 27
Clean the instrument body by removing dust gently with a dry, soft cloth. If the outside of the MagPurix 24 EVO system is heavily soiled, or if any sample that may cause infection are adhering to the outside of the MagPurix 24 EVO system, wipe with a soft paper tissue, soaked with 75% ethanol.
Leakage from Filter tipFilter tips or uneven Air leakage on the Filter Swap the air-leaked Tip with a new one liquid handling between Filter tips www.zinexts.com MagPurix 24 EVO Instruction Manual...
Page 29
DNA contaminated with Minimize the amount of blood or blood-stained sample heme used (≤ 20μl blood spot for forensics sample). DNA is sheared Bubbles form during To prevent bubble formation during mixing, make sure the www.zinexts.com MagPurix 24 EVO Instruction Manual...
Any consumption spare parts including fuses, light bulbs, UV lights, LED lighting sets. 3. For further information about the Warranty Policy and Extended Warranty offers, please contact your local representative / agent, or visit our website www.zinexts.com. www.zinexts.com MagPurix 24 EVO Instruction Manual...