Hayward EasyTemp ECPI15MA Installation Instructions Manual page 5

Swimming pool heat pump unit
Table of Contents

Advertisement

1. GENERAL INSTRUCTIONS - SAFETY (continued)
Installation conditions
This heat pump is designed exclusively to heat swimming pool water; do not
use this equipment for any other purpose.
Do not attempt to install this device by yourself.
If you detect a fault or any abnormal situation, do not install the heat pump
and contact your dealer immediately.
If kept in storage, the heat pump should be kept in a well-ventilated room with
a floor area of more than A
A
= (M/(2.5 x 0.22759 x h0))².
min
M is the quantity of refrigerant in the device in kg, and h0 is the storage
height. If stored no the floor, h0 = 0.6 m.
This product was designed exclusively for domestic use and installation
outdoors. The air that escapes from the product must be able to flow freely
and must not be used for other purposes such as heating or cooling a room
or building.
Check the power cable. If the power cable is damaged, it has to be replaced
by the manufacturer, its after-sales service or by a qualified and authorised
person.
Grounding connection of the device and its continuity are mandatory. The
ground wire has to be longer than the other wires in order to prevent the risks
of electric shock in the event the cable is pulled out. The electrical installation
must be equipped with a differential protection of 30 mA (see § 3.4).
Make sure the support provided for the unit is strong enough to bear the
weight of the unit.
Failure to comply with recommendations will invalidate the warranty.
Instructions for servicing - maintenance
Maintenance operations must be carried out once per year in order to guarantee
the longevity and the good working condition of the heat pump.
Maintenance and the different operations must be carried out at the
recommended times and frequencies as specified in this manual.
Only use genuine spare parts.
Check the power cable. If the power cable is damaged, it has to be replaced
by the manufacturer, its after-sales service or by a qualified and authorised
person.
Verify the grounding connection of the device and its continuity.
Clean the coil with the help of a soft brush or jet of air or water. Warning,
never use a high pressure cleaner.
(m²) as calculated by the following formula:
min
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Easytemp ecpi20maEasytemp ecpi30maEasytemp ecpi40ma

Table of Contents