Fujitsu AUXG07KVLA Service Manual page 374

Hide thumbs Also See for AUXG07KVLA:
Table of Contents

Advertisement

 Model: AOHG36KBTA5
Fan speed is defined by outdoor temperature and compressor frequency.
Fan step
S-HIGH
13
12
11
10
9
8
7
6
5
4
3
2
1
• When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed.
• When the compressor frequency decreases, the outdoor fan speed also changes to the lower
speed.
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 1,200 rpm
3-2. Outdoor fan control
Cooling or dry
1,150
1,150
1,150
1,080
920
860
770
680
630
560
490
390
270
- (04-54) -
Unit: rpm
Heating
1,200
1,200
1,150
1,080
990
860
800
700
640
600
570
3. Fan control