Zennio KIPI SC User Manual

Secure knx-ip interface

Advertisement

Quick Links

KIPI SC
Secure KNX-IP Interface
ZSYKIPISC
Application Program version: [1.1]
User Manual version: [1.1]_a
www.zennio.com

Advertisement

Table of Contents
loading

Summary of Contents for Zennio KIPI SC

  • Page 1 KIPI SC Secure KNX-IP Interface ZSYKIPISC Application Program version: [1.1] User Manual version: [1.1]_a www.zennio.com...
  • Page 2: Table Of Contents

    KIPI SC v1.1 CONTENTS Contents ..........................2 Document Updates ........................ 3 Introduction ........................4 KIPI SC ........................4 Installation ......................5 LED Indicators ......................6 Hard Reset to Factory Defaults ................7 Configuration ......................... 8 KNX to IP Interface ....................8 2.1.1 Programmer ......................
  • Page 3: Document Updates

    KIPI SC v1.1 DOCUMENT UPDATES Version Changes Page(s) Changes in the application program: [1.1]_a Date/time synchronisation via NTP https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 4: Introduction

    KNX bus and serve as the clock master of the installation. To ensure the exchange of KNX data in both IP and TP medium, the KIPI SC has been provided with KNX Secure. For detailed information about the functionality and configuration of the KNX security, please refer to the specific user manual "KNX...
  • Page 5: Installation

    DIN rail by the usual procedure The programming button (8) shown in Figure 1 programming button (8) may be pressed to set KIPI SC in programming mode. After a short press, the programming LED (7) will light in red.
  • Page 6: Led Indicators

    KIPI SC v1.1 1.3 LED INDICATORS KIPI SC incorporates four LED lights on the top of the device that make it easy to monitor the status of the buses and to detect typical communication problems, as detailed next. Figure 2 LEDs KNX Line Status LED (TP): shows the status of the primary bus.
  • Page 7: Hard Reset To Factory Defaults

    KIPI SC v1.1 1.4 HARD RESET TO FACTORY DEFAULTS If “IP Fact. Reset” button is pressed for three seconds, the device restores its default parameters (obtain an IP address via DHCP server). Thus, if a device becomes inaccessible on the local network due to the loss of its IP configuration, the device can be located again.
  • Page 8: Configuration

    Up to five simultaneous connections are allowed for performing downloads or for bus monitoring (via group monitor). Note: to detect the KIPI SC as a programmer in ETS, it needs to be connected to the same IP network as the PC.
  • Page 9 ETS is lost and the download is cancelled). 2.1.1.1 PROPERTIES Once the desire Interface KIPI SC has been selected, its configuration will be carried out in the “IP” panel of “Properties” tab in ETS: https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 10 Note: If a static IP is configured, it is important to make sure that no other device on the network has this IP assigned to it and that it does not belong to the DHCP range configured for the router, otherwise connection problems with the KIPI SC will be observed.
  • Page 11 Certain conditions must be met: Each download must be performed on a different line. For each line, it is necessary to select one KIPI SC to perform the download. Note: There is a restriction: parallel downloads are not available to download physical addresses.
  • Page 12: Addicional Individual Addresses (Tunneling Addresses)

    ETS after adding the device to the project, as shown in Figure 7: Figure 7. Set tunneling addresses. After the individual KIPI SC address has been set, the five tunneling addresses are automatically set with consecutive values. This can be changer at any time.
  • Page 13: General

    KIPI SC v1.1 2.2 GENERAL The only parameterizable screen available is “General”. All device functions can be activate/deactivate from this screen. ETS PARAMETERISATION Figure 8. General. Heartbeat (Periodic Alive Notification) [disabled/enabled]: incorporates a one-bit object to the project (“[Heartbeat] Object to Send ‘1’”) that will be sent periodically with value “1”...
  • Page 14: Ntp Clock

    2.3 NTP CLOCK KIPI SC can be configured as the installation master clock, it will send the date and time information to the rest of the devices of the installation. This information will be obtained from an NTP server.
  • Page 15: Annex I. Communication Objects

    KIPI SC v1.1 ANNEX I. COMMUNICATION OBJECTS “Functional Range” shows the values that, with independence of any other values permitted by the bus according to the object size, may be of any use or have a particular meaning because of the specifications or restrictions from both the KNX standard or the application programme itself.
  • Page 16 Join and send us your inquiries about Zennio devices: https://support.zennio.com Zennio Avance y Tecnología S.L. C/ Río Jarama, 132. Nave P-8.11 45007 Toledo, Spain. Tel. +34 925 232 002 www.zennio.com info@zennio.com...