Zennio Securel v2 User Manual

Zennio Securel v2 User Manual

Access controller–encrypted relay

Advertisement

Quick Links

Securel v2
Access Controller – Encrypted Relay
ZIOSECV2
dsñkmfroi
Application Program Version: 1.2
User manual edition: [1.2]_a
www.zennio.com

Advertisement

Table of Contents
loading

Summary of Contents for Zennio Securel v2

  • Page 1 Securel v2 Access Controller – Encrypted Relay ZIOSECV2 dsñkmfroi Application Program Version: 1.2 User manual edition: [1.2]_a www.zennio.com...
  • Page 2: Table Of Contents

    Securel v2 CONTENTS Contents ............................2 Introduction ..........................3 1.1 Securel v2 ................¡Error! Marcador no definido. 1.2 Access Control System ..................... 4 1.3 Installation ........................4 Pairing with IWAC ........................7 LED Notification ........................8 Securel v2 status ........................9 4.1 Default status ........................
  • Page 3: Introduction

    1 INTRODUCTION 1.1 SECUREL V2 Securel v2 from Zennio is a KNX actuator presented as a secure system for closing and opening doors of access-controlled rooms. It is located inside the room and it uses encrypted information to communicate with the access control device (for example, IWAC Display v3).
  • Page 4: Securel V2

    Securel v2: final element acting on the lock when granting access from IWAC. In the idle state, Securel v2 will keep the electric strike locked to prevent the door opening. When the Open command is correctly received from IWAC (access granted), Securel v2 will release the lock for a while to open the door.
  • Page 5: Installation

    (1) and any of its two neutral connectors (3). On the other hand, Securel v2 powers the electric strike also using one of the other positive supply terminals (1) and the terminal of the electric strike output as neutral (2).
  • Page 6 To get detailed information about the technical features of this device, as well as on the installation and security procedures, please refer to the corresponding Datasheet, bundled with the original package of the device and also available at www.zennio.com. http://www.zennio.com Technical Support: http://support.zennio.com...
  • Page 7: Pairing With Iwac

    To make it possible the communication between IWAC and Securel v2, they must be paired. The aim of the pairing is to ensure that the communication between these devices is exclusive, this means, Securel v2 will only handle orders from the IWAC to which is paired.
  • Page 8: Led Notification

    When the programming mode is activated, only this mode will be notified by lighting the LED in red. Note: Securel v2 can be paired or open/close the relay while the programming mode is active, but only the programming mode is notified (i.e., the LED remains lighting in red).
  • Page 9: Securel V2 Status

    The different performances that Securel v2 will have facing several possible situations during its operation are explained below. 4.1 DEFAULT STATUS In the factory default state, Securel v2 is in pairing mode. This way, Securel v2 will automatically pair with the first IWAC connected to it. 4.2 STATUS AFTER PROGRAMMING...
  • Page 10: Configuration

    Securel v2 5 CONFIGURATION 5.1 GENERAL After importing the corresponding database in ETS and adding the device into the topology of the desired project, the configuration process begins by entering Parameters tab of the device. ETS PARAMETERISATION The only parameterisable screen available is “General”. From this screen it is possible to configure all the required functionality.
  • Page 11 255 seconds, to prevent bus overload. The following sendings match the period set. Note Take into account that Securel v2 must be paired with the corresponding access control device (IWAC) to work properly (for further information, see section 2).
  • Page 12: Anexo I. Communication Objects

    KNX standard or the application programme itself. Number Size Flags Data type (DPT) Functional Range Name Function 1 Bit C T - - - DPT_Trigger [Heartbeat] Object to Send '1' Sending of '1' Periodically http://www.zennio.com Technical Support: http://support.zennio.com...
  • Page 13 Join and send us your inquiries about Zennio devices: http://support.zennio.com Zennio Avance y Tecnología S.L. C/ Río Jarama, 132. Nave P-8.11 45007 Toledo. Spain Tel. +34 925 232 002 www.zennio.com info@zennio.com...