Bosch Rexroth Diax 04 HVE Instruction Manual page 34

2nd generation power supply units
Table of Contents

Advertisement

5-18
Instructions for Use
Terminal assignment
Condition as supplied
Load capacity
Line 1L+ and 2L+ to choke
Design
Type
Number of poles
Type of design
Cross section [mm
Tightening torque
Fig. 5-49:
Design
Fig. 5-50: Terminal assignment
• HVE02/HVE03: with jumper from 1L+ to 2L+
• HVE04: without jumper
(if the optional choke is not required, a jumper has to be laid from 1L+
to 2L+; line cross section: see below)
max. voltage with reference to L-
voltage with reference to ground
max. continuous current
Fig. 5-51: Load capacity
line length
line cross section
line routing
dielectric strength of single strand
against ground
Fig. 5-52: Line 1L+ and 2L+
HVE02/HVE03
screw terminal
2
screw terminal for ring
cable lug M5
2
10...25
]
2,5...3,0
device external
device internal
optional
choke
GLD xx
1L+
2L+
DC 900 V
provided mains voltage
HVE02/03: 70 A
HVE04: 150 A
max. 10 m
not smaller than cross section of
supply feeder;
minimum cross section: see data
under "Design"
twisted
≥ 750 V
(e.g.: strand type – H07)
DOK-DIAX04-HVE+HVR*UL*-IB01-EN-P
Rexroth Diax 04 HVE/HVR
HVE04
screw terminal
2
multi-core with
connector sleeve or
single-core
16...50
6...8
X13
AP_X13.fh7