7. The display will confirm the chosen voltage and operation mode twice.
The PIN code can be reset by selecting the P option. Bluetooth pairing information needs to be removed from any previously
paired devices after selecting this option.
Bluetooth can be disabled/re-enabled by selecting F (enable) or H (disable).

4.2.3. Programming table

Programming table for Smart BatteryProtect 12/24V
7-segment display
Under voltage shutdown 12/24V system
0
1
2
3
4
5
6
7
8
9
-
A
b
C
d
F
h
P

4.3. Status indicator

The decimal point of the 7-segment display is used for status indication:
• Illuminated: the Smart BatteryProtect is attempting to activate the output.
• Flash every 5 seconds: output is active.
• Flash every 2 seconds whilst in Li-ion mode: output 'connecting'. When in Li-ion mode the SBP will observe a dead period of 30
seconds after the remote input of the SBP has become free floating.
Page 11
Smart BatteryProtect 12/24V
Push button
Push button wired to program the Smart BatteryProtect
10.5V/21.0V
10.0V/20.0V
9.5V/19.0V
11.25V/22.5V
11.5V/23.0V
10.5V/21.0V
11.5V/23.0V
11.8V/23.6V
12.0V/24.0V
10.0V/20.0V
User defined settings with Bluetooth
Buzzer or LED mode
Relay mode
Lithium mode
Detect system voltage
Bluetooth Enable
Bluetooth Disable
PIN code reset
Under voltage restart 12/24V system
12.0V/24.0V
11.5V/23.0V
11.5V/23.0V
13.25V/26.5V
13.8V/27.6V
12.8V/25.6V
12.8V/25.6V
12.8V/25.6V
13.0V/26.0V
13.2V/26.4V
Operation and programming