Thank you for buying the NOCO Genius ® Boost™ GB70. Read and understand the User Guide before operating the product. For questions regarding our jump starter, view our comprehensive support information at www.no.co/support. To contact NOCO for personalized support (not available in all areas), visit www.no.co/connect.
Phone: 1.800.456.6626
Email: support@no.co
Mailing Address: 30339 Diamond Parkway, #102, Glenwillow, OH 44139, United States of America
The NOCO Genius® Boost™ GB70 is an ultra-compact and portable lithium-ion jump starter for highdisplacement gas and diesel engines in cars, trucks, boats and more. Safe to use on engines of any size. It's extremely safe for anyone to use. It features spark proof technology and reverse polarity protection. The GB70 can instantly jump start most single-battery applications, up to 40 times on a single charge. The GB70 is also equipped with a USB battery pack, 12V OUT port and LED flashlight, making it the ultimate emergency tool.
The GB70 comes partially charged out of the box and needs to be fully charged prior to use. Carefully read and understand the vehicle owner's manual on specific precautions and recommended methods for jump starting the vehicle. Make sure to determine the voltage and chemistry of the battery by referring to your battery owner's manual prior to using this product. The GB70 is for jump starting 12-volt lead-acid batteries only.
Before connecting to the battery, verify that you have a 12volt lead-acid battery. The GB70 is not suitable for any other type of battery. Identify the correct polarity of the battery terminals on the battery. The positive battery terminal is typically marked by these letters or symbol (POS,P,+). The negative battery terminal is typically marked by these letters or symbol (NEG,N,-). Do not make any connections to the carburetor, fuel lines, or thin, sheet metal parts. The below instructions are for a negative ground system (most common). If your vehicle is a positive ground system (very uncommon), follow the below instructions in reverse order.
The GB70 is designed to jump start 12-volt lead-acid batteries down to 2-volts. If your battery is below 2-volts, the Boost LED will be "Off". This is an indication that the GB70 can not detect a battery.
If you need to jump start a battery below 2-volts there is a Manual Override feature, which allows you to force "On" the jump start function.
USE THIS MODE WITH EXTREME CARE. THIS MODE IS FOR 12-VOLT LEAD-ACID BATTERIES ONLY. BOTH THE SPARK PROOF AND REVERSE POLARITY PROTECTION FEATURES ARE DISABLED. PAY VERY CLOSE ATTENTION TO THE POLARITY OF THE BATTERY BEFORE USING THIS MODE. DO NOT ALLOW THE POSITIVE AND NEGATIVE BATTERY CLAMPS TO TOUCH OR CONNECT TO EACH OTHER AS THE PRODUCT WILL GENERATE SPARKS. THIS MODE USES VERY HIGH CURRENT (UP TO 2000 AMPS) THAT CAN CAUSE SPARKS AND HIGH HEAT IF NOT USED PROPERLY. IF YOU ARE UNSURE ABOUT USING THIS MODE, DO NOT ATTEMPT AND SEEK PROFESSIONAL HELP.
Before using the Manual Override feature, make sure the HD battery clamps are connected to the correct polarity battery terminals. To use the Manual Override feature, press and hold the Manual Override Button (a red exclamation point icon inside a red circle) for three (3) seconds. The White Boost LED will flash "On" and "Off" indicating you have successfully entered into Manual Override and it is ready to jump start your vehicle. If connected in reverse polarity, the Red Error LED will illuminate and the unit will not operate.
POWER THE GB70 "OFF" BEFORE DISCONNECTING THE BATTERY CLAMPS. THIS WILL ENSURE YOUR SAFETY. REMEMBER BOTH THE SPARK PROOF AND REVERSE POLARITY PROTECTION FEATURES ARE DISABLED.
Most vehicles will immediately start. Some vehicles may require the GB70 to be connected for up to 30 seconds before starting. If the vehicle does not start right away, wait 20-30 seconds and try again. Do not attempt more than five (5) consecutive jump starts within a fifteen (15) minute period. Allow the GB70 to rest for fifteen (15) minutes before attempting to jump start the vehicle again.
The GB70 has four (4) Charge LEDs - 25%, 50%, 75% and 100%. These Charge LEDs indicate the internal battery's state-of-charge (SOC). See below:
LED | Explanation |
25% Red LED | The 25% Charge LED will be solid when the internal battery is 25% or less charged. |
50% Red LED | The 50% and 25% Charge LEDs will be solid when the internal battery is more than 25% but less than 50% charged. |
75% Yellow LED | The 75%, 50%, and 25% Charge LEDs will be solid when the internal battery is more than 50% but less than 75% charged. |
100% Green LED | All four (100%, 75%, 50%, and 25%) Charge LEDs will be solid when the internal battery is more than 75% up to 100% charged. |
The above charge states apply when the GB70 is NOT connected to a power supply and recharging.
LED | Explanation |
25% Red LED | The 25% Charge LED will slowly pulse "On" and "Off", when the battery is less than 25% charged. When the battery is 25% charged, the Red Charge LED will be solid. |
50% Red LED | The 50% Charge LED will slowly pulse "On" and "Off", when the battery is less than 50% charged. When the battery is 50% charged, the Red Charge LED will be solid. |
75% Yellow LED | The 75% Charge LED will slowly pulse "On" and "Off", when the battery is less than 75% charged. When the battery is 75% charged, the Yellow Charge LED will be solid. |
100% Green LED | The 100% Charge LED will slowly pulse "On" and "Off", when the battery is less than 100% charged. When the battery is fully charged, the Green LED will be solid, and the 25%, 50% and 75% Charge LEDs will turn "Off". |
The GB70 shall display an Error Condition when a reverse polarity condition is present, a battery below two (2) volts, or the internal battery overheating. When one of these Error Conditions are present, the following will happen:
Error | Reason/Solution |
Error LED Solid Red | Reverse polarity/ Reverse the battery connections. |
Error LED Blinking Red w/Cables Connected Properly | The internal battery is too hot/ Allow the unit to cool. Bring the unit into cooler environment. |
Boost Light Does Not Come On w/Cables Connected Properly | Connected battery is below 2-volts/ Remove all loads, and try again, or use Manual Override Mode. |
12V Fast Charge (36W):
Connect the 12V Cable to the "12V IN" port on the GB70, and the other end to the Male 12 Plug. Plug into a powered 12V AUX Plug (Cigarette Lighter Port.)
USB Charging (Up to 10W):
Connect the GB70 using the included USB Charge Cable to the USB IN port and a powered USB port, like an AC adapter, car charger, laptop and more. The USB IN port is rated at 2.1 Amps to ensure safe and efficient charging of the internal lithium battery.
Due to FCC regulations, we do not recommend charging and discharging the unit at the same time.
The time to recharge a GB70 will differ based on the discharge level and the power source used. Actual results may vary due to battery conditions.
USB Charger Rating | 12V Fast Charge | |||
.5A | 1A | 2A | 3A @ 12V (36W) | |
Time | 28hr | 14hr | 7hr | 2-3hr |
You can recharge virtually any USB device, like a smartphone. Connect the included USB Charge Cable to the USB OUT port and connect to your USB device.
The number of times you can recharge a USB device will vary between devices. For recharge times, contact your device manufacturer.
Connect the 12V Cable to the "12V OUT" port on the GB70, and the other end to the Female 12V Plug (12V AUX/ Cigarette Lighter Port.) Plug-in any standard 12V device (Up to 15A) with a 12V plug and turn the GB70 "On" to start powering your device.
The GB70 has an integrated ultra-bright LED flashlight. It has seven (7) light modes that effect its performance and longevity: 100%, 50%, 10%, SOS, Blink, Strobe, and Off.
To turn the flashlight "On" and "Off", use the Power button with the light bulb icon. Press once to turn the flashlight "On" at 100% luminosity, again for 50% luminosity (within 3 seconds), again for 10% luminosity (within 3 seconds), again for SOS (within 3 seconds), again for Blink (within 3 seconds), again for Strobe (within 3 seconds) and again for "Off". If a light mode is not selected within 3 seconds, it will remain "On" in the current light mode, and the next selection will turn the flashlight "Off".
Depending on the mode selection, the GB70 will have various levels of output and runtime. Selecting a lower power level when using the GB70 for extended periods of time will prolong battery life.
Modes:
100% > 50% > 10% > SOS > Blink > Strobe > Off
Internal Battery: | Lithium Ion |
Peak Current Rating: | 2000A |
joules3S: | 15700+ |
Operating Temperature: | -30°C to +50°C |
Charging Temperature: | 0ºC to +40ºC |
Storage Temperature: | -20ºC to +50ºC (Avg Temp.) |
Micro USB (Input): | 5V, 2.1A |
USB (Output): | 5V, 2.1A |
12V (Input) | 12V, 3A |
12V (Output) | 12V, 15A |
Housing Protection: | IP65 (w/Ports Closed) |
Cooling: | Natural Convection |
Dimensions (L x W x H): | 8.6 x 6 x 2.5 Inches |
Weight: | 5 Pounds |
The GB70 has a built in energy saving feature that will automatically turn the unit off after seven (7) hours. To continue using, simply power on the unit again.
1.800.456.6626
support@no.co
30339 Diamond Parkway, #102
Glenwillow, OH 44139
United States of America
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the Boost HD GB70 that isn't answered in the manual? Leave your question here.