Installation - Bluegrass Living B30TD-BL Owner's Operation And Installation Manual

Vent-free gas wall fireplace
Table of Contents

Advertisement

NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri-
mary heat source. If you have a
central heating system, you may
run system's circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualified ser-
vice person must install heater.
Follow all local codes.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 36" from
the front, top, or sides of the
heater
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
cause walls to discolor.
200470-01A

INSTALLATION

IMPORTANT: Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation air
may cause mildew to form too much moisture.
See Air for Combustion and Ventilation, pages
7 and 8.
Be sure your gas supply is right for your heat-
er. Otherwise, call dealer where you bought
the heater for proper type heater.
Carefully follow the instructions below. This
heater is a freestanding unit designed to be
mounted on a wall or set on a base.
minimum clearances shown in
Figure 4. If you can, provide
greater clearances from floor,
ceiling, and joining wall.
Figure 4 - Mounting Clearances as
This heater is designed to be mounted on a
wall. For convenience and efficiency, install
heater:
1. Where there is easy access for operation,
2. In the coldest part of room.
www.bluegrassliving.com
CHECK GAS TYPE
CLEARANCES TO
COMBUSTIBLES
WARNING: Maintain the
CEILING
8"
Minimum
From
Sides of
Heater
Left
Side
5" Minimum to Top Surface of Carpeting,
Tile or Other Combustible Material
FLOOR
Viewed From Front of Heater
LOCATING HEATER
inspection, and service.
36"
Minimum
Right
Side
9

Advertisement

Table of Contents
loading

Table of Contents