Bluegrass Living B30TD-BL Owner's Operation And Installation Manual page 17

Vent-free gas wall fireplace
Table of Contents

Advertisement

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2
PSIG (3.5 kPa)
1. Disconnect heater with its appliance main
gas valve (control valve) and equipment
shutoff valve from gas supply piping sys-
tem. Pressures in excess of 1/2 PSIG will
damage heater regulator.
2. Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane supply tank valve for
propane gas or opening main gas valve
located on or near gas meter for natural
gas or using compressed air.
4. Check all joints of gas supply piping sys-
tem. Apply a noncorrosive leak detection
fluid to gas joints. If bubbles form, there
may be a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff
valve to gas supply. Check reconnected
fittings for leaks.
Test Pressures Equal To or Less
Than 1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Fig-
ure 17).
2. Pressurize supply piping system by either
opening propane supply tank valve for
propane gas or opening main gas valve
located on or near gas meter for natural
gas or using compressed air.
3. Check all joints from gas supply (see Fig-
ure 18 or 19) to equipment shutoff valve.
Apply a noncorrosive leak detection fluid
to all joints. Bubbles forming show a leak.
4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open equipment shutoff valve (see Fig-
ure 17).
2. Open main gas valve located on or near
gas meter for natural gas or open propane
gas supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from equipment shutoff
valve to control valve (see Figure 18 or
200470-01A
INSTALLATION
Figure 17 - Equipment Shutoff Valve
Propane
Supply Tank
Figure 18 - Checking Gas Joints for
Gas Meter
Figure 19 - Checking Gas Joints for
5. Correct all leaks at once.
6. Light heater (see Lighting Instructions on
7. Turn off heater (see To Turn Off Gas Ap-
www.bluegrassliving.com
Equipment
Shutoff Valve
Propane Gas
Equipment Shutoff Valve
Natural Gas
19). Apply a noncorrosive leak detection
fluid to all joints. Bubbles forming show a
leak.
page 18). Check all other internal joints
for leaks.
pliance, page 19).
Open
Closed
Gas Valve
Equipment
Shutoff Valve
Gas Valve
17

Advertisement

Table of Contents
loading

Table of Contents