2-2 Mechanical Adjustment
Note : Refer to the Mechanical Manual "TS-10A (AC82-00023A)" for the adjustment and confirmation of
ass'y full deck.
2-2-1 The number and position of test point
Test point :
TP301 (Envelope)
TP302 (Audio output)
TP602 (H'D S/W -Trigger)
2-2-2 ACE Head Position (X-Point) Adjustment
(See the 2-2-1(d) ACE Head Position (X-Point) Adjustment
on page 2-2 of the Mechanical Manual)
1) Playback the alignment tape (Color bar).
2) Press the "TEST" button on Main PCB/F/AV
PCB/Function PCB to set the adjustment mode.
(See Fig. 2-2, 2-3, 2-4 and 2-5)
3) Press the "5" button of remote control then
adjustment is operated automatically. (See Fig. 2-1)
Samsung Electronics
PRESS
Fig. 2-6 Location of Test point (Main PCB-Top View)
4) Connect the CH-1 probe to TP301 (Envelope) the
CH-2 probe to TP602 (H'D switching pulse) and
then trigger to CH-1.
5) Insert the (-) driver into the X-Point adjustment
hole and adjust it so that envelope waveform is
maximum.
6) Turn the Power off.
Alignment and Adjustment
2-5