Wiring - Scheiber BLOC 11 User & Troubleshooting Manual

Table of Contents

Advertisement

Wiring

1
Connect to each connector:
- either a CAN connection cable
(to another Multibloc compatible device)
- or a 120Ω impedance matching plug.
Connect the equipment to the pins according to the numbering available in the table below, then plug
2
the MPC connector into the TYCO receptacle.
crimp pins x21
Crimp pin
MCP connector
Designation
1
S1_NO
2
S1_C
3
E1_NUM_PLUS
4
S2 _NO
5
S2 _C
6
E2_NUM_PLUS
7
S3_NO
8
S3_C
9
E3_NUM_PLUS
10
S4_NO
11
S4_C
12
E4_NUM_PLUS
13
S5_NO
14
S5_C
15
E5_NUM_PLUS
16
S6_NO
17
S6_C
18
E6_NUM_PLUS
19
+ BAT
20
CODING
21
MASS
L'innovation française depuis 1965
or
120Ω
CAN
Termination
cable
1
2
3
Description
NO Contact Relay n°1
Common relay contact n°1
Plus digital input for momentary switches N°1
NO Contact Relay n°2
Common relay contact n°2
Plus digital input for momentary switches N°2
NO Contact Relay n°3
Common relay contact n°3
Plus digital input for momentary switches N°3
NO Contact Relay n°4
Common relay contact n°4
Plus digital input for momentary switches N°4
NO Contact Relay n°5
Common relay contact n°5
Plus digital input for momentary switches N°5
NO Contact Relay n°6
Common relay contact n°6
Plus digital input for momentary switches N°6
Power supply input 8-32VDC
Coding input
Battery mass
P.6
L'innovation française depuis 1965
CAN
CAN
cable
cable
4
7
10
13
16
19
5
8
11
14
17
20
6
9
12
15
18
21
TYCO receptacle

Advertisement

Table of Contents
loading

Table of Contents