Installation Instructions; Connection - Scheiber BLOC 11 User & Troubleshooting Manual

Table of Contents

Advertisement

Installation instructions

• This device must be placed in a place protecting it from any risk of water splashing. Install in a ventilated location
• Do not install on supports that are sensitive to heat, such as carpet or PVC flooring, etc.
• The product must be installed away from heat and humidity
WARNING: Connection/disconnection with power on
!
Do not perform connection or disconnection with power on.
Mounting
119,50
100
Mounting distance :
100 x 59 mm

Connection

INPUT / OUTPUT / POWER SUPPLY
Type of connection
Cross section
CAN BUS
PROTECTION TO BE PROVIDED ON THE SUPPLY LINE
Protection rating
Protection location
Push-button
MCP2,8 - 21Pts (BROWN) housing connectors
Ref. Scheiber 0E.CON1430
Ref. Tyco 8-968975-1 MCP2,8GEH21P
MCP2,8 Receptacle 0,5-1,0mm2 tinned
Ref. Scheiber 0E.CLP360
Ref. Tyco 1-968849-1
Extraction tool for MCP contacts
Réf. Tyco 1-1579007-2
2 x CAN connectors type 6-way Micro-Fit
Fuse or circuit breaker 5A
Accessible and identified for the user
Input 1 ... 6 (-)
BLOC 11
C
Relays 1 ... 6
NO
P.5
L'innovation française depuis 1965
L'innovation française depuis 1965
77,51
20
Coding
19
21

Advertisement

Table of Contents