Wiring Configuration And Connector Accessories - schmersal AZM300Z-I2-ST-1P2P-N-DU Operation And Assembly Instructions

Solenoid interlock
Table of Contents

Advertisement

Y1 and Y2 = Safety outputs → Safety monitoring module
Wiring example 2: Series-wiring of the AZM300 with serial diagnostic function (max. 31 components in
series)
In devices with the serial diagnostics function (ordering suffix -SD), the serial diagnostics connections are wired in
series and connected to a SD-Gateway for evaluation purposes. The safety outputs of the first safety component are
wired to the safety-monitoring module. The serial Diagnostic Gateway is connected to the serial diagnostic input of the
first safety component.
Y1 and Y2 = Safety outputs → Safety monitoring module
SD-IN → Gateway → Field bus

4.4 Wiring configuration and connector accessories