Emergency Exit -T/-T8 Or Emergency Release -N - schmersal AZM300Z-I2-ST-1P2P-N-DU Operation And Assembly Instructions

Solenoid interlock
Table of Contents

Advertisement

p
.
Caution: do not turn beyond the end stop!
Key
A: connector plug M12, 8-pole
B: LED display
C1: Manual release by means of slotted screwdriver
C2: Manual release by means of triangular key TK-M5
The manual release must be protected against accidental actuation, e.g. by using the enclosed seal after completing
commissioning.

3.3 Emergency exit -T/-T8 or emergency release -N

With variants that have both emergency exit and emergency release, the red lever is loosely supplied. Before first use,
mount the lever on the triangular part of the release using the screw supplied so that the arrow in the triangle and pin
on the red lever are congruent.
The installation of the lever is possible on both sides. The opposite side can be used as a manual release by means of a
triangular key TK-M5.