ATTACH OPTIONAL BACK TRIM
The back trim is an optional piece that can be added for a more
built-in appearance. To attach the back trim to the unit, simply screw
it into the back of the unit with provided screws.
The height of the back trim is adjustable for various fitment styles.
To raise or lower the back trim, loosen the screws slightly and adjust
the back trim, then tighten the screws.
back trim can be raised or lowered for various fitment styles
raised
Back Trim flush with
elevated rangetop

ELECTRICAL CONNECTIONS

If codes permit and a separate ground wire is used, it is recommended
that a qualified electrical installer determine that the ground path is
adequate and wire gauge is in accordance with local codes.
IN U.S.A.
Be sure the electrical connection and wire size are adequate and in
conformance with the National Electrical Code, ANSI/ NFPA No.
70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
nfpa.org/Codes-and-Standards
IN CANADA
Be sure the electrical connection and wire size are adequate and in
conformance with CSA standard C22.1, Canadian Electrical Code,
Part 1 - latest edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
csagroup.org/standards
E
flush
Back Trim back
trim left off
6

ELECTRICAL REQUIREMENTS

This unit must be supplied with the proper voltage and frequency
and connected to an individual, properly grounded branch circuit,
protected by a circuit breaker or fuse having amperage as noted on
the rating plate.
BREAKER OR FUSE SIZE
240V
208V
NOTE: Check local codes for required breaker size.
All electrical wiring and hookup for this unit must be done by a
qualified electrician. Make note of the location of the main appliance
disconnect.

POWER CONNECTIONS

This unit is manufactured with a neutral (white) power supply wire
and a cabinet-connected (green) grounding wire.
Connect the unit cable to the junction box through the UL-listed
conduit connector. Complete electrical connection according to
local codes and ordinances. See page 3 for junction box or electrical
outlet locations.
NOTE TO ELECTRICIAN: The armored cable leads supplied
with this unit are UL recognized for connection to larger gauge
household wiring. The installation of the leads is rated at tempera-
tures much higher than the temperature rating of household wiring.
The current carrying capacity of the conductor is governed by the
temperature rating of the installation around the wire, rather than
the wire gauge alone.
NOTE:
• The proper size wire nut shall be placed over the stripped leads
and the wire nut twisted until the wire nut can not be pulled from
the leads. No conductor shall be exposed in the connection.
• Do not shorten the flexible conduit. The conduit strain relief clamp
(supplied by installer) must be securely attached to the junction
box, and the flexible conduit must be securely attached to the
clamp. If the flexible conduit will not fit with the junction box, do
not install the unit until a clamp of proper size has been obtained.
40 Amps