11. Troubleshooting guide

Faults
Pump fails
The intake line has a leak or
to prime
is damaged
Priming takes a very long
time
Clogging in the intake line
Pump housing with no pum-
ped medium.
Intake cage not in water.
Air cannot escape
Anl_AQUINNA_18_30_F_LED_SPK13.indb 24
Anl_AQUINNA_18_30_F_LED_SPK13.indb 24
GB
Possible cause
Check the following points for leaks:
- Intake line
- Water fi lling screw / water drain screw / ventilation
- Connection points of the intake line
- Check the intake height
- Priming can take up to 5 minutes
- Always position the intake line so that it rises / is
Check and clean the following points:
- Intake line
- Priming area
- Intake cage (incl. non-return valve)
- Coarse fi lter (incl. non-return valve)
Fit the following to protect the pump:
- Intake cage
- Coarse fi lter
Fill the pump housing with pumped medium.
Dip the intake cage into water. Make sure that the
immersion depth / quantity of water is suffi cient for
the level not to drop below the intake cage when
water is drawn off .
- Open the corresponding shut-off devices (spray
- When the pump is being fi lled, open the ventila-
- 24 -
Remedy
screw / coarse fi lter cap
horizontal
nozzles, valves etc.) in the discharge line. Begin
with the shut-off devices closest to the pump.
tion screw so that air can escape from the pump
housing.