Dc Wiring - Cobra PI2000 Operating Instructions Manual

2000 watt power inverter
Table of Contents

Advertisement

DC Wiring

DC Wiring
DC Wiring
1. Be sure the ON/OFF switch on the inverter is
CAUTION: Loosely tightened
in the OFF position.
connectors result in excessive
voltage drop and may cause
over heated wires and melted
insulation.
CAUTION: Reverse polarity
connections (positive to nega-
2. Connect the cables to the power input termi-
tive) will blow internal fuses in
nals on the rear panel of the inverter. The red
the inverter and may perma-
terminals are positive(+) and the black termi-
nently damage the unit. Such
nals are negative (-). Insert the bare ends of
damage is not covered by the
the cables into the terminals and tighten the
warranty.
screws to clamp the wires securely.
CAUTION: We recommend a
main fuse in the battery's posi-
tive cable to protect against
DC wiring short circuits (exter-
nal to the inverter). The fuse
should be as close to the bat-
tery as possible. We recom-
3. Connect the cable from the negative terminal
mend a Buss Fuse ANL-250 or
of the inverter to the negative terminal of the
equivalent. The specific fuse
battery. Make a secure connection.
ampere rating should be sized
4. Double check that the cable you just installed
to allow operation of all your
connects the negative terminal of the invert-
DC powered equipment.
er to the negative terminal of the battery.
Power connections to the inverter must be
positive to positive and negative to negative.
12
5. Connect the cable from the positive terminal
of the inverter to the positive terminal of the
battery's main fuse, or to the battery selector
switch, if you are using one. Make a secure
connection.
You might observe a spark when you make this
connection since current can flow to charge
capacitors in the inverter.
Operation.
Turn the inverter On by using the ON/OFF switch
on the left side panel .
The inverter is now ready to deliver AC power to
your loads. If several loads are to be operated by
the inverter, turn them on separately, after the
inverter has been turned On. This will ensure that
the inverter does not have to deliver the starting
currents required for all the loads at once.
DC Wiring
WARNING: Do not make this
connection in the presence of
flammable fumes. Explosion or
fire may result. Thoroughly
ventilate the battery compart-
ment before making this con-
nection.
13