Advertisement

Quick Links

CUT 40CT
PLASMA CUTTING MACHINE
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CUT 40CT and is the answer not in the manual?

Questions and answers

Summary of Contents for Riland CUT 40CT

  • Page 1 CUT 40CT PLASMA CUTTING MACHINE USER MANUAL...
  • Page 2 Preface This manual includes hardware description and operation introduction of equipment. For your and other people’s safety, please read the manual carefully. Pay attention Pay attention to the words after the signs below. Sign Description The words after this sign means there is great potential danger, which may cause major accident, damage or even death, if it is not followed.
  • Page 3: Table Of Contents

    CONTENTS SAFETY WARNING ........................... 4 MACHINE DESCRIPTION ......................... 9 TECHNICAL PARAMETERS TABLE ........................10 INSTALLATION INSTRUCTION ........................ 11 AIR REGULATOR INSTALLATION AND OPERATION ..................12 PANEL FUNCTION INSTRUCTION ......................13 OPERATION INSTRUCTION ........................14 NOTES OR PREVENTIVE MEASURES ....................15 QUESTIONS TO BE RUN INTO DURING CUTTING ..................
  • Page 4: Safety Warning

    SAFETY WARNING The safety notes listed in this manual is to ensure correct use of the machine and to keep you and other people from being hurt. The design and manufacture of plasma cutting machine considers safety. Please refer to the safety warning listed in the manual to avoid accidents.
  • Page 5 Please follow the rules below to avoid heavy accidents. Never use the equipment to do other things but cutting. Follow related regulations for the construction of the input-driven power source, choice of place, usage of high-pressure gas, storage, configuration, safe-keeping of workpiece after cutting and disposal of waste, etc.
  • Page 6 Keep hot workpiece after cutting away from flammable gas. Do move away the combustible around when cut the dooryard, ground and wall,. The wire connection of base metal should be as close to the cutting place as possible. Never cut those facilities with gas pipe or airtight slot. Put fire extinguisher around the cutting area to prevent fire.
  • Page 7 Fix the gas cylinder with appropriative holder and other relative parts. Never put the cylinder under high temperature or sunshine environment. Keep your face away from the gas cylinder exit when opening it. Put on the gas shield when it is not used. Never put the torch on the gas cylinder.
  • Page 8 Lifting way for the machines with swing ring on the top(φ≤15°) Electromagnetic interference needing attention. It may need extra preventive measures when the equipment is used in particular location. Before the installation, please estimate the potential electromagnetism problems of the environment as follows.
  • Page 9: Machine Description

    MACHINE DESCRIPTION The plasma welding machine adopts the most advanced inverter technology, it’s applicable for plasma cutting system with compressed air. The development of welding and cutting equipment benefits from the appearance of the inverter power supply theory and components. Inverter cutting machine, firstly transfers the working voltage of 50/60Hz to high frequency (above 100KHz) via high-power device MOSFET, then reduces the voltage and adjusts the current, delivers high-power cutting current via PWM technology.
  • Page 10: Technical Parameters Table

    TECHNICAL PARAMETERS TABLE Model CUT 40CT Parameters Input voltage(V) AC220V15% Frequency(Hz) 50/60 Rate input current(A) No-load voltage(V) Current Range(A) 15-40 Rate output voltage(V) Duty cycle(%) Efficiency(%) Power factor 0.78 Insulation Class Housing Protection Class IP21 Arcing Way Contact Pressure of air compressor (Kgf/cm Limited cutting thickness(mm)...
  • Page 11: Installation Instruction

    7. Connect the cable as the picture shows, you can start cutting. Related Parts Specification Model CUT 40CT Rated current ≥4mm Input side ≥6 mm Cable Output side ≥4 mm...
  • Page 12: Air Regulator Installation And Operation

    AIR REGULATOR INSTALLATION AND OPERATION 1. Firmly tight and seal the copper air hole at IN and OUT terminal by high pressure rubber tube firmly. 2. Tight and seal the meter with meter face rubber tube. 3. Fix the sheet holder with screw as the regulator position. 4.
  • Page 13: Panel Function Instruction

    PANEL FUNCTION INSTRUCTION Post gas adjusting knob Power indicator Abnormal indicator Welding current adjusting knob Positive output terminal Plasma cutting torch switch socket Negative output terminal The panel picture above is for reference only. If any difference with the real machine, please follow with the real machine.
  • Page 14: Operation Instruction

    OPERATION INSTRUCTION 1. Turn on the power switch of front panel, make the power switch is in “on” position. At this time indicator of power switch is on. 2. Adjust the gas pressure to be adequate to machine, turn on the valve of pressed air. 3.
  • Page 15: Notes Or Preventive Measures

    NOTES OR PREVENTIVE MEASURES Environment 1) The machine can perform in environment where conditions are dry with a dampness level of max 90%. 2) Ambient temperature is between -10 to 40 degrees centigrade. 3) Avoid cutting in sunshine or drippings. Do not let water enter the gas. 4)...
  • Page 16: Questions To Be Run Into During Cutting

    QUESTIONS TO BE RUN INTO DURING CUTTING Fittings, cutting materials, environment factor, supply powers maybe have something to do with cutting. User must try to improve cutting environment. A. Cutting surface is rough, poor cutting result. The machine may be not well operated. You can check it as follow: 1.
  • Page 17: Maintenance

    MAINTENANCE WARNING: Power must be turned off for all checking and maintenance, before opening the housing, make sure the power plug is disconnected. 1. Remove dust by dry and clean compressed air regularly, if plasma cutting machine is operating in environment where is polluted with smokes and pollution air, the machine need removing dust every day.
  • Page 18: Troubleshooting And Fault Finding

    TROUBLESHOOTING AND FAULT FINDING Notes: The following operations must be performed by qualified electricians with valid certifications. Before maintenance,please contact with us for professional suggestion. Fault symptom and solutions Faults Solutions 1. Power switch is out of work. Power indicator is not lit fan 2.
  • Page 19 1. Primary cable of arc-striking transformer is not connected to power panel firmly, tighten it again. Abnormal indicator is not lit, 2. Arc-striking tip is oxidized or too far, give a good polish to it or sound of HF arc-striking change it is about 1 mm between arc-striking tip.
  • Page 20: Circuit Diagram

    CIRCUIT DIAGRAM...