7.0 SPECIFICATIONS

FIELDMETER/POWER SUPPLY
Sensor: Vibrating Reed
Range: ±20 kV @ 1" (25.4mm)
Display: 3 ½-Digit LCD
Resolution: 1V (10V as a Fieldmeter)
Accuracy: ±10% (Fieldmeter)
Linearity: ±10%
HVPS: ±1200V (approx)
Timer: 0-60 sec. (0-6 sec. optional)
Accuracy: 5% of Reading
Resolution: 0.3 sec. (0.03 sec.)
Rec. Out:
2.5 mm Jack
Signal: 10 mV/kV (200mV FS)
Power: 9V Battery
Life: 20 Hrs. typical.
Bat Low: All decimal pts. Illuminated
CHARGED PLATE DETECTOR
Capacitance: 20±3pf
Detector Plate: 1"x3" (2.5x7.6cm)
Plug-in option:.6"x6" (152x152mm)
Accuracy: ±20%
Ground:
Cord: 10' (3m)
Connection: ¼" (6mm) Male Snap
MECHANICAL
Dimensions: 8"Lx2.4"Wx0.9"H (203x146x229mm)
Weight: 9 oz. (255gm)
Case: Conductive