Testing for Loop Pair Insulation Resistance
The purpose of verifying the loop pair insulation resistance test is to establish the insulation has not broken down
to the point of a short circuit condition.
Test Parameters:
Insure the outboard side of the cable pairs have each been shorted.
Insure that NO surge protection devices are in place during the verification testing.
Insure NO cable pair bridge taps have been inserted.
Insure that NO power has been applied to the cable pairs during this test.
Procedure
Using your multi-meter set for ohms (resistance) measurement. IF any pair reads less than 100K ohm, discard that
pair. For each cable pair, measure the value of insulation resistance between the following terminals.
Between Tip and Ring
Between Tip and Ground
Between Ring and Ground
Note: If the insulation resistance reads less than 100K ohms on any pair, do not use for Line Power.