Download Print this page

ABB CP3200 Quick Start Manual page 3

+/- 190vdc line power circuit cable

Advertisement

QUICK START GUIDE
Testing for The Presence of DC Voltage:
Using your multi-meter set for DC voltage, measure for the presence of DC voltage between the following:
Between Tip and Ring
Between Tip and Ground
Between Ring and Ground
Note: If voltage is present on any of the preceding measurements for each cable pair, note that cable pair in the
following table 1. That DC fault must be cleared to proceed in using that cable pair.
Adjust the meter to read DC voltage and carefully connect the multimeter leads to the RING and TIP terminals for
each cable pair connection. If any DC voltage is measured, record the data in Table 1.
Adjust the meter to read DC voltage and carefully connect the multimeter leads to the RING and GROUND terminals
for each cable pair connection. If any DC voltage is measured, record the data in Table 1.
Adjust the meter to read DC voltage and carefully connect the multimeter leads to the TIP and GROUND terminals
for each cable pair connection. If any DC voltage is measured, record the data in Table 1