Download Print this page

Axis Emergency Stop Reset; Operation - Daewoo TAPER 40 Operation Manual

Advertisement

3.7.6 Axis emergency stop reset

Operation becomes impossible with MACHINE READY button extinguished, when the emer-
gency stop switch is actuated, just after power on or on other occasion.
At this time, reset the state following the process described below.
3
4
5
Inspection/adjustment/maintenance

3. Operation

Step
Operation
1
Check AXIS
EMERGENCY STOP
2
Check the machine state
3
Push MACHINE
READY and EMER-
GENCY RELEASE button
simultaneously
4
Reset
5
Select JOG or HANDLE
mode
6
Return the axis into travel
range with JOG or HAN-
DLE with pushing
MACHINE READY and
EMERGENCY RELEASE
button simultaneously
1. Be careful of the direction and motion when the overtrav-
eled axis is returned into travel range. Severe collision
can be occured.
3 – 34
Location
MDI/CRT
– Check the axis and direction
devices
– Operation call lamp lighting
Each axis
– Check collision and
interference, and repair
Main OP. panel
– Button lighting
after flickering
– Operation possible
– Refer to 3.3.11
VMCTOPES8D51
Remark
3.3.12

Advertisement

loading

This manual is also suitable for:

Taper 50