Read through the safety information and operating instructions carefully before using your Waterous Fire
Pump.
Hose Testing Hazard. May result in serious personal injury.
Due to a potential for catastrophic hose failure during service testing of fire hose, it is vital that safety precautions be taken to
prevent exposure of anyone to this danger. Fire pumps on fire department apparatus are not designed for and should not be
used for service testing of fire hoses. Hose testing machines should be used for service testing of fire hoses.
Pressure Hazard. May result in serious personal injury.
If a fire pump on a fire department apparatus is used for service testing of fire hoses, the procedures in NFPA 1962 MUST be
followed including the use of a fire department gate valve with a ¼-inch (6 mm) hole drilled through the gate installed
between the fire apparatus discharge outlet and the hose test layout to prevent a volume surge from the pump in the event a
hose bursts during testing.
Scalding Water Hazard. May result in serious burns.
If a fire pump on a fire department apparatus is used for service testing of fire hoses, pump discharge water must be
circulated through a by-pass system or discharged through a slightly open discharge valve, or some other provision must be
used to prevent overheating. If the pump runs for a few minutes without adequate flow through the pump, water may be
heated enough to scald someone when a valve is opened.
F-1031, Section 2109.1