• Works with Electronic Low-Voltage and Incandescent Loads but not exceeding 1000W/VA.
• Works with any Dimensions 3200 Series Multizone Controller/Dimmer to extend load capacity on
Power Extender
Dimming Control
The Leviton Power Extender, Cat. No. PE400-1, will emulate the characteristics of the dimmer that it is
connected to in terms of dimming range and resolution.
Cat. No. PE400-1
Compatibility
Rating: 1000W/VA
120VAC, 60Hz
For use with Electronic Low-Voltage
and Incandescent fixtures
NOTE: For dimmers that include a Neutral wire, the dimmer Neutral wire must be connected.
For more information go to
www.leviton.com
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
INSTALLATION INSTRUCTIONS
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
DI-000-PE400-00B
WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE
ELECTRICAL CODES AND REGULATIONS.
WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
QUALIFIED ELECTRICIAN.
Leviton warrants to the original consumer purchaser and
not for the benefit of anyone else that this product at the
OTHER CAUTIONS:
time of its sale by Leviton is free of defects in materials and
workmanship under normal and proper use for two years
1. BOTH LIGHTING FIXTURE AND CONTROLLER MUST BE GROUNDED.
from the purchase date. Leviton's only obligation is to correct
such defects by repair or replacement, at its option, if within
2. DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING LAMPS.
such two year period the product is returned prepaid, with
proof of purchase date, and a description of the problem to
3. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE
Leviton Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New
York 11362-2591 (In Canada send to Leviton Mfg. of
NOTE: The Power Extender must be installed in a 1900 Box with Raised Cover or a properly
Canada Ltd., 165 Hymus Blvd., Point Claire, (Quebec),
Canada H9R 1E9). This warranty excludes and there is
grounded metal 2-gang wall box, 3.5" (8.9 cm) deep (refer to Figure 1A and1B). Depending on the
disclaimed liability for labor for removal of this product or
application and the number of connections, more space may be needed. If so, use an appropriate size
reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded,
box or box extension.
misused, opened, abused, or altered in any manner, or is
not used under normal operating conditions or not in
TO INSTALL:
accordance with any labels or instructions. There are no
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKERS
other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if
any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty,
including merchantability and fitness for a particular purpose,
is limited to two years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including
2. Remove 1/2" (1.3 cm) of insulation from each circuit conductor in wall box. Make sure that ends of
without limitation, damage to, or loss of use of, any
equipment, lost sales or profits or delay or failure to perform
this warranty obligation. The remedies provided herein are
3. Connect lead wires per appropriate WIRING DIAGRAM and FIGURE 2 as follows: All connections
the exclusive remedies under this warranty, whether based
on contract, tort or otherwise.
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
DI-000-PE400-00B
DI-000-PE400-00B
1
FEATURES
any zone.
DESCRIPTION
• Box Mounted Dimmers – Must use a 120V, 600W Incandescent version of the following
families: Monet, Illumatech, Mural, Sureslide, True Touch, Touch Point, and Home Control.
• D3200 – All Dimensions Multizone Controllers.
• Architectural Systems – Works with all families.
FCC COMPLIANCE STATEMENT
INSTALLATION INSTRUCTIONS
USE ONLY DEVICES MARKED CO/ALR OR CU/AL.
OR FUSES AND TEST THAT POWER IS OFF BEFORE WIRING!
MORE THAN ONE CIRCUIT BREAKER CAN POWER THIS DEVICE. DISCONNECT "ALL"
POWER SOURCES BEFORE SERVICING CONTROL.
conductors are straight.
to the output terminals should be made using #12 AWG wire. Each power terminal can accept up to
two(2) #12 wires. The recommended installation torque is 9.0 in.-lbs. for line voltage connections.
Figure 1A: Surface Mounting
1900 Box
2 Gang Raised Cover
Raised Cover
Mounting Screws
(4 Places)
Power
Extender
Power Extender
Wallplate
Figure 3: Front View
Figure 2: End View
TOP
4. Carefully position all wires to provide room in wall box for Power
Extender.
When mounting, all PEAUXS must be spaced 4-1/2"
and below each unit for proper ventilation and heat dissipation
(refer to Figure 4). Line voltage wiring should be at least 6 ft. away
from sound or electronic equipment wiring. Mount Power Extender
to outlet box with "TOP" facing up (refer to Figure 3).
For Wall Box Mounting: Refer to Figure 1A.
For Flush Mounting: Refer to Figure 1B.
For Panel Mounting (not shown), Proceed as follows:
a. The enclosure must be in accordance with all local and national electrical codes.
b. Leviton DOES NOT recommend using a door to enclose the front of a panel, since this restricts
airflow to the controls.
c. If mounting multiple controls in an enclosure:
• Ambient temperature within an enclosure "MUST REMAIN BETWEEN" 32˚-104˚F (0˚-40˚C).
• If not mounting in a metal enclosure, all units "MUST" be mounted in a wall box.
d. To improve heat dissipation of controls, remove the faceplate from the unit.
5. Restore power at circuit breaker or fuse.
6. Turn ON the dimmer.
7. Using the dimmer control, verify that the load DIMS and BRIGHTENS smoothly and the lamps do
not flicker.
8. If desired, attach wallplate by aligning tabs on back of plate with grooves in fins on Power Extender
(refer to Figure 1A and Figure 1B). INSTALLATION IS COMPLETE.
3/19/04, 10:20 AM
Figure 1B: Flush Mounting
1900 Box
2 Gang Raised Cover
Raised Cover
Mounting Screws
(4 Places)
Power
Extender
Power Extender
Wallplate
Figure 4: Front View Spacing
TOP
4-1/2" (11.4 cm)
Minimum
TOP
4-1/2" (11.4 cm)
Minimum
above