LMP-0500 Series User Manual V1.1
LMX-0500 Series
5-Port Industrial Managed Ethernet Switch, with
5*10/100Tx, 12~48VDC Power Input
User Manual
Version 1.1
i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LMP-0500 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ANTAIRA LMP-0500 Series

  • Page 1 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMP-0500 Series User Manual V1.1 LMX-0500 Series 5-Port Industrial Managed Ethernet Switch, with 5*10/100Tx, 12~48VDC Power Input User Manual Version 1.1...
  • Page 2 Trademark Information Antaira is a registered trademark of Antaira Technologies, LLC, Microsoft Windows and the Windows logo are the trademarks of Microsoft Corp. NetWare is the registered trademark of Novell Inc. WMM and WPA are the registered trademarks of Wi-Fi Alliance.
  • Page 3 Industrial Grade Managed Ethernet Switches User Manual Version 1.1 (March 2018) This manual supports the following models: LMX-0500  LMX-0500-T  This document is the current official release manual. Please check our website (www.antaira.com) for any updated manual or contact us by e-mail (support@antaira.com).
  • Page 4: Table Of Contents

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Table of Contents 1. Introduction....................1 1.1 Product Overview ................1 1.2 Product Software Features ............1 1.3 Product Hardware Features ............2 1.4 Package Contents ................. 2 1.5 Safety Precaution ................
  • Page 5 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.3.2 Port Configuration ..............17 5.5 ERPS ................... 19 5.5.1 ERPS Status ................20 5.5.2 ERPS Configuration ............... 20 5.5.3 Before Configuring ERPS ............22 5.6 Spanning Tree ................
  • Page 6 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.12.2 System Event Log ..............46 5.12.3 SMTP Setting ............... 47 5.12.4 Event Selection ..............48 5.12.5 Fault Alarm................48 5.13 MAC Table… ................49 5.13.1 MAC Address Table .............
  • Page 7: Introduction

    LMP-0500 Series User Manual V1.1 1. Introduction All Antaira industrial managed switches come with a pre-installed “user friendly” web console interface, which allows users to easily configure and manage the units, whether one is using a serial console and command line interface(CLI) commands like Telnet, SSH, HTTP (Web GUI) or simple network management protocols (SNMP).
  • Page 8: Product Hardware Features

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1  Software Upgrade via TFTP and HTTP  Configuration Backup – USB Port 1.3 Product Hardware Features  System Interface and Performance  All RJ-45 ports support Auto MDI/MDI-X Function Embedded 5*10/100Tx Fast Ethernet ports ...
  • Page 9: Hardware Description

    LMX-0500 Series User Manual V1.1 2. Hardware Description 2.1 Physical Dimensions Figure 2.1, below, shows the physical dimensions of Antaira’s LMX-0500 series: 5-Port industrial managed Ethernet switch with 5*10/100Tx; 12~48VDC power input. (W x D x H) is 46mm x 99mm x 142mm Figure2.1...
  • Page 10: Front Panel

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 2.2 Front Panel The front panel of the LMX-0500 series industrial managed Ethernet switches is shown below in Figure 2.2. Figure 2.2 - The Front Panel of LMX-0500 Series 2.3 Top View...
  • Page 11: Led Indicators

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 2.4 LED Indicators There are LED light indicators located on the front panel of the industrial Ethernet switch that display the power status and network status. Each LED indicator has a different color and has its own specific meaning, see below in Table 2.1.
  • Page 12 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 without changing the straight-through or crossover cabling. See the figures as below for straight- through and crossover cabling schematics.  RJ-45 Pin Assignments (Table 2.2)
  • Page 13: Cabling

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 2.6 Cabling  Twisted-pair segments can be connected with an unshielded twisted pair (UTP) or shielded twisted pair (STP) cable. The cable must comply with the IEEE 802.3u 100Base TX standard (e.g.
  • Page 14: Wiring The Fault Alarm Contact

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 2.8 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture shows below in Figure 2.8.
  • Page 15: Mounting Installation

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 3. Mounting Installation 3.1 DIN-Rail Mounting The DIN-Rail is pre-installed on the industrial Ethernet switch from the factory. If the DIN-Rail is not on the industrial Ethernet switch, please see Figure 3.1 to learn how to install the DIN-...
  • Page 16: Wall Mounting

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 3.2 Wall Mounting Follow the steps below to mount the industrial Ethernet switch using the wall mounting bracket as shown below in Figure 3.4.
  • Page 17: Hardware Installation

    LMX-0500 Series User Manual V1.1 4. Hardware Installation 4.1 Installation Steps This section will explain how to install Antaira’s LMX-0500 series: 5-Port industrial managed Ethernet switch with 5*10/100Tx RJ45 ports; 12~48VDC power input. Installation Steps 1. Unpack the industrial Ethernet switch from the original packing box.
  • Page 18: Web Management

    This section introduces the configuration by web browser. 5.1.1 About Web-Based Management All of Antaira’s industrial managed switches are embedded with HTML web console interfaces that have a flash memory on the CPU board. It is a “user friendly” design with advanced management features that allow users to manage the switch from anywhere on the network through any Internet browser, such as Internet Explorer (version 9.0 or above is recommended),...
  • Page 19: Basic Setting

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 3. The login screen appears. 4. Key in the default username: admin and password admin. 5. Click “Login” button, then the main (status) page of the Web Console will appear as below Figure 5.2.
  • Page 20: Admin &Password

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Terms Value Description Factory Default: Switch *Users can assign any name label to identify this managed node. By convention, a domain name is a text string drawn from System Name the alphabet (A-Z, a-z), digits (0-9), minus sign (-).
  • Page 21: Ip Setting

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Terms Value Description New Password Users can assign a New Password, and the maximum allow string length is 0 to 31 characters. Confirmation Re-type the new password.
  • Page 22: System Time

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Subnet Mask Assign the subnet mask of the IP address. If DHCP client function is enabling, user does not require to assign the subnet mask Gateway Assign the network gateway for the switch.
  • Page 23: Port Management

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.3Port Management 5.3.1 Port Status The following information provides the current port status. Figure 5.11 – Port Status Interface 5.3.2 Port Configuration Users can assign or insert a “value/label” for each port under each “Port Name” box; enable or disable each port function;...
  • Page 24 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Terms Value Description Port No. It shows each port status: Up for link active, and Down for link inactive. Port Name User can create or insert a value or label for each port’s identification...
  • Page 25: Erps

    Antaira is proud to introduce and implement Ethernet Ring Protection Switching (ERPS) protocol as a standard ring solution for network redundancy with all new industrial managed Ethernet switches.
  • Page 26: Erps Status

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.5.1 ERPS Status Below, Figure 5.18, shows the network redundancy ring status with the Ethernet Ring Protection Switch (ERPS) protocol. Figure 5.14 – Redundant Ring Network – ERPS Status 5.5.2 ERPS Configuration...
  • Page 27 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Terms Value Description Protocol “Enable” or “Disable” ERPS protocol ERPS ring port 0, it could be map to real switch port 1 – port 6.
  • Page 28: Before Configuring Erps

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.5.3 Before Configuring ERPS Before configuring ERPS, the rapid spanning tree protocol (RSTP), or multiple spanning tree protocol is required to disabled, due to only one protocol is exclusive running within a switch.
  • Page 29 ERPS, which are “RPL Owner Node”, “RPL Neighbor Node”, and “Normal Node”. Below are two scenarios describing how to configure the ERPS in Antaira Industrial Managed Ethernet Switches. Users can reference it to configure the managed switch as...
  • Page 30 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.5.3.1 Scenario A – RPL configured Architecture Under this scenario A, there are three major roles are required to be configured within the ERPS configuration.
  • Page 31 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 [RPL Owner Node] There is only one RPL Owner Node could be set in a ring network. In order to set up the RPL Owner Node, choose a switch and enable “Protocol” under the ERPS Configuration interface, and follow below steps and use below figure 5.25 as example:...
  • Page 32 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 [RPL Neighbor Node] Users should choose a second managed switch that is adjacent to the first managed switch and set it up as the RPL neighbor node. For configuration, users should login to the second managed switch’s ERPS configuration interface and choose a specific port number under...
  • Page 33 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 [Normal Node] Then user should setup the rest of the managed switches’ “Role” of both “Ring Port 0 and 1” as “Normal Node” as shown above in Figure 5.23. Please be sure no duplicate port number has been chosen within a managed switch’s ERPS ring setting, the incorrect configurations...
  • Page 34 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.5.3.2 Scenario B – Non-configured Architecture In some situations, users can choose not to configure the RPL owner and neighbor node; the ERPS could still work well under the mechanism by blocking one of the ring ports in the ERPS ring topology.
  • Page 35: Spanning Tree

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Figure 5.25 – Non-configured Architecture setup 5.6 Spanning Tree The Spanning Tree Protocol (STP), defined in the IEEE Standard 802.1d, can be created within a mesh network of connected layer-2 switches.
  • Page 36: Rstp Status

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.6.1 RSTP Status Figure 5.26 shows the RSTP algorithm results. Figure 5.26 – RSTP Information Interface 5.6.2 RSTP Configuration Users can enable/disable the RSTP function, and set the parameters for each port.
  • Page 37 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Terms Value Description Users can select RSTP or MSTP function to be enabled or Mode disabled before configuring the related parameters. A value used to identify the root bridge. The bridge with...
  • Page 38: Msti Status

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 The port includes the STP mathematic calculation. Admin Non STP True is not including STP mathematic calculation. False is including the STP mathematic calculation.
  • Page 39: Msti Configuration

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.6.4 MSTI Configuration Users can display the MSTI root status and port status by selecting the “Instance ID” number from 1 to 15 by clicking on the dropdown box from the “MSTI Status” interface.
  • Page 40 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Click “Apply” button to save changes. Figure 5.31 – MSTI Configuration –Terms & Value Description Figure 5.32 – MSTI Port Configuration Interface Terms Value Description...
  • Page 41: 802.1Q Vlan

    PVID. All of Antaira’s industrial managed switches’ have a default VLAN setting set to “none” for each port, so the users can login to the VLAN setting interface to create a VLAN Group name and choose “Tag”...
  • Page 42: 802.1Q Vlan Settings

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.7.2 802.1Q VLAN Settings Figure 5.35 – 802.1Q VLAN Settings Interface Terms Value Description PVID User can assign a Port VLAN ID for each port User can choose any port be “Tagged”...
  • Page 43: Igmp Settings

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 decreases the workload at the end hosts since their network cards (or operating system) will not receive and filter all the multicast traffic generated in the network.
  • Page 44: Igmp Snooping Status Table

    Traffic Prioritization includes three modes: port base, 802.1p/COS, and TOS/DSCP. By traffic prioritization function, users can classify the traffic into four classes for differential network application. All of Antaira’s industrial managed switches support four priority queues.
  • Page 45: Qos Classification

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.9.1 QoS Classification Figure 5.40 – QoS Classification Interface Terms Value Description User can set it as “Weighted” or “Strict” Weighted mode: An 8, 4, 2, 1 weighting is applied to each round robin priority queue.
  • Page 46: Cos Mapping

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 7 is the Lowest Click “Apply” button to save changes. Figure 5.41 – QoS Classification Terms & Value Description 5.9.2 CoS Mapping Figure 5.42 – CoS Mapping Interface...
  • Page 47: Tos Mapping

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.9.3 ToS Mapping ToS is an acronym for Type of Service. It is implemented as the IPv4 ToS priority control. It is fully decoded to determine the priority from the 6-bit ToS field in the IP header. The most significant 6 bits of the ToS field are fully decoded into 64 possibilities, and the singular code that results is compared against the corresponding bit in the IPv4 ToS priority control bit (0~63).
  • Page 48: Port Mirroring

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.10 Port Mirroring Enable or disable mirroring feature. When enabled, a copy of matched frames will be mirrored to the destination port specified in the port mirroring interface.
  • Page 49: Snmp

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.11 SNMP Simple Network Management Protocol (SNMP) is the protocol developed to manage nodes (servers, workstations, routers, switches and hubs etc.) on an IP network.
  • Page 50: Snmp Trap Setting

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.11.2 SNMP Trap setting Figure 5.50 – SNMP Trap Setting Terms Value Description Enable SNMP Trap Enable SNMP Trap function by check the box...
  • Page 51: System Warning

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.12 System Warning System warning function is very important for managing a switch. Users can manage the switch by “Syslog”, “System Event Log”, and “Email Server” setup for Advanced Notice in any event type, “Event Type Selection”, and “Fault Alarm”...
  • Page 52: System Event Log

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Click “Apply” button to save changes. Figure 5.53 – SYSLOG Setting Terms & Value Description 5.12.2System Event Log Users can view and display the system event log by clicking the “Apply” button on the right bottom corner of the interface.
  • Page 53: Smtp Setting

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.12.3 SMTP Setting The Simple Mail Transfer Protocol (SMTP) is for e-mail transmission across the Internet. Figure 5.55 – SMTP Setting Interface Terms Value Description E-mail Alert Enable/Disable transmission system warning events by e-mail.
  • Page 54: Event Selection

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.12.4 Event Selection Users can select any event type through the “Event Selection” interface, such as “System Cold Start”, any ports’ “Link Up”, “Link Down”, “Link Up & Link Down” and send the system warning massage to either SYSLOG or SMTP, or both at the same time.
  • Page 55: Mac Table

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.13 MAC Table The MAC address table is the filtering database that supports queries by the forwarding process, as to whether a frame received by a given port with a given destination MAC address is to be forwarded through a given potential transmission port.
  • Page 56: Maintenance

    Antaira is continuously developing new functions and features for specific application requirements for the industrial managed switches. Users can download the latest firmware from Antaira’s website and store it within their local PC, server, or USB drive. Figure 5.61 – Firmware Upgrade Interface...
  • Page 57: Reboot

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.14.2 Reboot Users can click the “Apply” button under the “Reboot” interface to reboot the switch. Figure 5.63 – Switch Reboot Interface 5.14.3 Default Users can reset the switch to “Factory Default”...
  • Page 58: Save

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 5.15.1 Save Users can click the “Save” button under the “SAVE CONFIGURATION” interface, once all the settings had been configured. Figure 5.65 – Save Setting Interface 5.15.2...
  • Page 59: Auto Load & Backup

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 USB Management Fill in the folder and filename and click the button of Save Running Config to USB Backup. If the folder or filename does not exist, system will generate it automatically.
  • Page 60: Command Line Interface Management

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 6. Command Line Interface Management 6.1 About CLI Management Besides WEB-based management, LMX-0500 series also supports CLI management. Users can use console or telnet to management switch by CLI.
  • Page 61 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Step 2: Input a name for the new connection. Step 3: Select to use COM port number...
  • Page 62 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Step 4: The COM port property settings are as follows: 115200 for “Bits per second”, 8 for “Data bits”, None for Parity, 1 for “Stop bits” and none for “Flow control”.
  • Page 63 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 CLI Management by Telnet Users can use “TELNET” to configure the switches. The default value is as below:  IP Address: 192.168.1.254  Subnet Mask: 255.255.255.0 ...
  • Page 64 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 Commander Groups Command Mode Group hostname [Switch] configure system location [none] configure system contact [none] configure no system location configure no system contact configure...
  • Page 65 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 ntp sync minute [time] configure ntp sync hour [time] configure ntp sync day [time] configure ntp sync month [time] configure ntp sync weekly [time]...
  • Page 66 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 show flowcontrol interface show administrate interface show name interface show link status interface show link state interface show link speed interface show duplex interface...
  • Page 67 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 enable g8032 disable g8032 rpl [port0 | port1] [owner | neighbor] g8032 aps-channel [channel ID] g8032 revertive g8032 clear g8032 port0 interface [interface name]...
  • Page 68 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 spanning-tree auto-edge off interface spanning-tree admin-edge on interface spanning-tree stp disable interface no spanning-tree enable configure no spanning-tree mode configure no spanning-tree priority configure...
  • Page 69 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 no spanning-tree mst name configure no spanning-tree mst revision configure no spanning-tree mst instance [instance_ID] vlan configure no spanning-tree mst [instance_ID] cost interface no spanning-tree mst [instance_ID] port-priority...
  • Page 70 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 event syslog warm-start enable configure event syslog authentication-failure enable configure event syslog erps-change enable configure event syslog interface [INTERFACE_NAME] [up | down] configure no event syslog power1...
  • Page 71 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 smtp enable configure smtp sender [E-MAIL_ADDR] configure smtp subject [subject_text] configure smtp server address [GMAIL_SMPT_SERVER] configure smtp server port [GMAIL_SMPT_SERVER] configure smtp authentication enable...
  • Page 72 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 no snmp server v3 encryption [admin | user] configure show snmp server enable configure show snmp server community [ro | rw] configure show snmp server v3 level [admin| user]...
  • Page 73 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 show snmp trap v3 level configure SNMP show snmp trap v3 engine-ID configure show snmp trap v3 auth configure show snmp trap v3 encryption...
  • Page 74 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 igmp snooping querier enable configure igmp snooping fast-leave enable interface no igmp snooping enable configure no igmp snooping query max-respond-time configure no igmp snooping query interval...
  • Page 75 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 2. CLI : enable -> configure terminal ->copy startup-config usb (path) Fill in the folder and filename behind the “copy startup-config usb” command. Ex: file1, / folder /file2.
  • Page 76 All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 4. CLI : enable -> configure terminal ->copy usb firmware (path) Fill in the folder and filename behind the “copy usb startup-config” command. Ex: file1, / folder /file2.
  • Page 77: Technical Specification

    All manuals and user guides at all-guides.com Antaira Industrial Ethernet Switches LMX-0500 Series User Manual V1.1 7. Technical Specification Table 7.1 has the technical specifications for Antaira’s LMX-0500 series: 5-Port industrial managed Ethernet switch with 5*10/100Tx; 12~48VDC power input. IEEE 802.3 10Base-T 10Mbit/s Ethernet IEEE 802.3u...
  • Page 78 UL 61010-1, UL 61010-2-201 Table 7.1 - LMX-0500 Series Technical Specification Antaira Customer Service and Support (Antaira US Headquarter) + 844-268-2472 (Antaira Europe Office) + 48-22-862-88-81 (Antaira Asia Office) + 886-2-2218-9733 Please report any problems to Antaira: www.antaira.com support@antaira.com www.antaira.eu info@antaira.eu www.antaira.com.tw...