  • Page 1: User Guide

    User Guide D4200 RCHITECTURAL ONTROL TATION Software revision 2.0 and above...
  • Page 2 NOTES:...
  • Page 3: Table Of Contents

    Dimmer Readback ...31 Double Bump ...32 LCD Backlight ...33 Time Master ...34 Old Code Compatibility...35 IR Control ...36 Astronomical Clock Setup ...36 Max. Number of Zones Setup ...38 Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller ECOMMENDATIONS ROGRAMMING ... 2 ... 19...
  • Page 4 Changing the MAX and OFF Lighting Levels ...62 Using the Optional Remote Control ...63 Viewing Scheduled Events...64 Viewing the Sequencer ...64 A - S PPENDIX B - L PPENDIX Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller ... 54 ONTROLS ... 66 ETUP ABLES ATITUDE AND ONGITUDE ...
  • Page 5 User Guide C - M ... 79 PPENDIX ISCELLANEOUS NFORMATION Clearing the Stations Memory...79 Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller...
  • Page 6: Warnings

    Indoor use only. TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT MAIN CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING! Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller User Guide Page 1 of 80...
  • Page 7: Installation Recommendations

    Assign unique network ID numbers to stations. Connect one master station, and then one remote control station at a time. Verify that the first D4200 can properly control the dimmers assigned to it. Check the proper operation of each station as it is installed when multiple stations are involved.
  • Page 8: Installation

    One Unit Load = 25mA Control Station A Unit Load Quantity of Station A's attached Figure 1 - Load Rating Verification Formula Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Control Station B Unit Load Same formula for any other attached...
  • Page 9 NPC – DHV NPC – DLR i-Series e Dimmer Rack Topaz/ENR Dimmer Rack Table 1 - Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Maximum # of Unit Loads 0 (no Luma-Net) Consult Factory Use DLR or NPC XP as Power...
  • Page 10 Use these quantities along with the Load Rating verification formula (Figure 1) to do the math and verify that the combined unit input load does not exceed the maximum input Unit Load Available. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Unit Load Station Type...
  • Page 11: Power Requirements And Max Wire Lengths

    The maximum run length, in feet based on the total number of unit loads is shown below: Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Unit Loads User Guide Total...
  • Page 12: Terminating The Wire

    The 2000 ft. limitation is a RS485 digital communications specification. The power supply pair must be sized correctly for the control stations that are connected to them. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller 12 AWG (Feet) 1904 3000...
  • Page 13 Note: a-2000D Cabinet can be in the middle of a daisy chain Figure 2 - The Right and Wrong Way to Run Luma- Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller The Right Way- With a Hub! LUMA-NET III HUB...
  • Page 14: Luma-Net Iii Wire Recommendations

    Manufacturer Catalog Number Belden 9729, 9829 Belden 9841 Belden 88102 Alpha 6222C Alpha 6412 Table 4- Luma-Net Recommended Wire Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller User Guide # of Pairs 2 (Plenum Rated) Page 9 of 80...
  • Page 15 Drain/Shield Table 5 - Color Coding for Belden Wire Foil Belden 9729 Figure 3 - Belden Wire Callouts Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller No. Pair Pin/Terminal N/C - Not Con- nected N/C - Not Con- nected...
  • Page 16: Wiring The Phoenix Connector

    Install termination jumpers as required. Remember a Step 5: termination jumper is required at the two ends of the Luma-Net run. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller User Guide Page 11 of 80...
  • Page 17 Figure 4 - Luma-Net Wiring Connections PRESET SELECT STATION Ground Shield only! at one point Figure 5 - Luma-Net Termination Jumper Locations Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Phoenix Connector Terminate LumaNet in these locations D4200 CONTROL STATION User Guide Black (Common)
  • Page 18: Testing The Wiring

    1-2 Open 2-3 Open 3-4 Open Repair any short circuits before continuing. Step 2: Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller User Guide Termination Jumper Phoenix Connector Page 13 of 80...
  • Page 19: Configuring The Dimmer Cabinets

    Install the Unit to the Wall Remove faceplate. Step 1: Insert wired phoenix connector into D4200 unit, per Figure Step 2: Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller User Guide Page 14 of 80...
  • Page 20 Mount Controller in 4-gang, gang box (10 Step 3: in deep) with 4-gang device cover (10 in. or Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller in. deep) as per Figure 8. User Guide C ontrol W ire P hoenix C onnector in.
  • Page 21 Figure 8 - Mounting Illustration Carefully position all wires to provide room in gang box for Step 4: D4200 LCD station. Mount the D4200 to raised cover using the screws provided. Be careful and do not overtighten the screws. See Figure 8.
  • Page 22: Power Up The Unit

    Note: You need to set a unique number from 001 to 127 for it to function. Press the Select/Save button to save the values. Step 2: MANUAL MODE M18 MON 12:00P Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down buttons to change the MAIN MENU User Guide Page 17 of 80...
  • Page 23: Checking The Version And Network Id

    Your version number should be the same or greater than this manual. You are now ready to proceed with Initial Setup and Programming. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller button once and the desired menu Software version number...
  • Page 24: Initial Setup And Programming

    • Assign Zones • Edit Network Network ID • Change Personalities • Miscellaneous Settings: Flags Setup Astronomical Time Set the Maximum number of Zones Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller User Guide Page 19 of 80...
  • Page 25: Main Menu Flow Chart

    MENU RECORD LOCK=OFF STATION LOCK=OFF MENU MENU STATION LOCK=ON RECORD LOCK=ON Figure 9 - LCD Screen Shots of Main Menu Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller MANUAL MODE G1 M18 MON 12:30P MENU MENU VIEW SEQUENCER SCHEDULER=OFF MENU...
  • Page 26: Programming And Configuration Level Flowchart

    EDIT NETWORK ASSIGN ZONES: Z01:CIRCUIT=0001 ASSIGN ZONES: START CHANN=0001 Figure 10 - LCD Screen Shots of Programming and Configuration Level Menu’s Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Programming and Configuration Level Menus MENU SET PERSONALITY ID=000 PERSONALITY: 01...
  • Page 27 Station Lock: ON or OFF Record Lock Code: (Default-000) Station Lock Code: (Default-000) Table 6 - User Setting’s for Easy Setup Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller User Setting’s Use Zone Patching and Label Chart Use Scheduling Chart...
  • Page 28: Navigating Menus

    P3 indicates Zone 17-24 and P4 indicates to Zones 25-32 are active. Scene Name Breakfast S01 TUE 04:29p LE Days of week Scene # Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Select Menu Clear Save Cancel . Moves the cursor back and forth, or .
  • Page 29: Programming And Configuration Level Menu

    When you are finished using the Setup menu selections, be sure to return to the regular menu. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller User Guide button for at least 10 Page 24 of 80...
  • Page 30: Setting The Network Id

    LEVITON appears on the LCD display. Wait until the LCD display changes to MANUAL MODE. Step 2: Operate the buttons on the D4200 one at a time. Pressing two or more buttons at once may not yield the desired result.
  • Page 31 The Network ID number flashes. Press the Up Step 5: value. You need to set a unique number from 001 to 127 for it to function. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller or Down MENU EDIT NETWORK and Down User Guide...
  • Page 32: More On Network Ids And Remote Ids

    Note: “Remote” Entry stations also have two net IDs, their Network ID and their master’s Net ID, otherwise known as their “REMOTE TO” or “TARGET” ID. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Right buttons to toggle to...
  • Page 33: Assigning Zones (Patching)

    04. The default setting is generally satisfactory for most simple installations with one or two D4200 controls and one dimmer cabinet. Setting START CHANN to a number causes all zones to be assigned to sequential channel numbers starting with that same number and adding one to each zone there after.
  • Page 34: Misc. Settings Menu

    The following list of individually setable option flags. Use to indicate the feature is ON, and use “ feature is OFF. By default these options are all OFF (lower case) Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down to set the value to...
  • Page 35 • IR Control: Allows the user to select if the IR port is active or disabled. On indicates that the IR port is active. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller MISC. SETTINGS: FLAGS= r b L T o I...
  • Page 36: Dimmer Readback

    The first one is the dimmer “Readback. If it is “lower” case the option is OFF. If it is “UPPER” case the option is ON. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down buttons until MISC. User Guide...
  • Page 37: Double Bump

    Press the Select/Save button. Step 6: The Dimmer Readback value flashes. Press the Right Step 7: The Double Bump value flashes. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down and Right and Down MENU MISC. SETTINGS? button to move to the next field.
  • Page 38: Lcd Backlight

    1.3 - Setting the LCD Backlight Time Out Flag This flag allows the backlight on the LCD to turn off after 60 seconds of no button presses on the D4200 station. To enable this feature: Access the Programming and Configuration Level menu Step 1: Press the Menu/Cancel button.
  • Page 39: Time Master

    Step 10: 1.4 - Setting the Time Master Flag This flag allows this D4200 station to take over as the Time Master. In this mode, a Time Master is the unit on the network that emits the time of day / date settings every 60 seconds. This helps all products that use the time / date information to stay synchronized.
  • Page 40: Old Code Compatibility

    Step 10: 1.5 - Previous Code Compatibility This flag allows this D4200 station to work with units that have previous code installed on them. This usually occurs when a LCD station is upgraded to new code, but the entry stations are not. For installs where only the 2.xx code resides, you want to make sure that...
  • Page 41: 1.6 - Ir Control

    Step 10: 2 - Setting up the Astronomical Clock The D4200 allows you to turn lights on or off in relation to sunrise and sunset. For example, yard lights can be set to turn on an hour before sunset, and turn off an hour after sunrise, according to the time of year.
  • Page 42 Press the Right Step 10: The minute value flashes. Press the Up Step 11: minutes. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller or Down MISC. SETTINGS: FLAGS=rblto - - - or Down MISC. SETTINGS: SETUP ASTROTIME? or Down SUNRISE= www.srrb.noaa.gov/highlights/sunrise/sunrise.htm...
  • Page 43: Max. Number Of Zones Setup

    24 Zones: “P1-P3” is displayed by the top right 2 Step 3: characters, indicating zones 1 to 8, 9 to 16 or 17-24 are being displayed. When you reach “P3” the Zone number Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller SUNSET= www.srrb.noaa.gov/highlights/sunrise/sunrise.htm and Down...
  • Page 44: Personalities

    (choir performance) set of Scenes could be recorded without disturbing the normal Sunday church service settings. The following information will need to be re-entered for each personality: Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller or Down MISC. SETTINGS: FLAGS=rblto - - -...
  • Page 45: Main Level Menus - Setup

    Test each station by raising and lowering each zone that is assigned to a dimmer. Check to see that control of the dimmer cabinet or other control device is correct and smooth. Main Level Menus Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down MENU SET PERSONALITY?
  • Page 46: Scheduling

    Scheduling The D4200 is already programmed to accept up to 64 possible Events, numbered E01 through E64. The default values are 12:00a (12:00 am), NONE (no Scene), and SMTWTFS (all days of the week). To create Events you must edit the schedule and change the default...
  • Page 47 Press the Select/Save button to save these values for Step 15: the Event. The Event number flashes again. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller button to move to the next field. and Down to return the value to Clear button to move to the next field.
  • Page 48: Enabling The Scheduling

    (GOTO a specific step). There is a table provided in Appendix A to help you set up the sequencer schedule. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down buttons to select menu command.
  • Page 49: Editing The Sequencer

    • LOOP • GOTO _ _ • SKIP • Scene (With Delay Time) • MAX • OFF Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down Time until next step and Down and Down to change the value to...
  • Page 50: Enabling The Sequencer

    You can program alphanumeric labels with up to 14 characters for any Scene MAX, OFF or Zone ID buttons. To name a Scene or a Zone: Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down and Down value flashes.
  • Page 51 Figure 12 - Shortcut for Alpha Keys Press the Select/Save button to save the value and edit Step 7: the label. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down button you want to edit. and Right and Down to clear the entire value.
  • Page 52: Zone Excludes

    24, page 4 is zones 25 to 32. Use Clear to clear all “excludes” i.e. to include all zones. By default all zones are included. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down EXCLUDE: SELECT A SCENE TO EDIT...
  • Page 53: Setting Date And Time

    Setting the date and time will set date and time on all other stations on the same lighting control network (using the Luma-Net™ data protocol). Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller buttons uses the last preset/scene’s zone and Down field flashes.
  • Page 54: Editing Daylight Savings Time Region

    Press the Select/Save button to record the change. Step 6: Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller (Adds 1 hour to displayed time from 1st Sunday in (Adds 1 hour to displayed time from Last Sunday of and Down field flashes.
  • Page 55: Locks

    Press the Up Step 2: RECORD LOCK? flashes on the LCD display. Press the Select/Save button. Step 3: The CODE field flashes Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down User Guide MAX. buttons until SET Page 50 of 80...
  • Page 56: Setting The Station Lock Code

    Press the Menu/Cancel button to exit this menu. Step 7: Enabling the Record Lock Be sure to set the Record Lock code before enabling the Record Lock. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down to reset the value to Clear flashes again.
  • Page 57: Enabling Station Lock

    Press the Select/Save button to save the value. Step 5: STATION LOCK= Press the Menu/Cancel button to exit this menu. Step 6: Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down and Down to change the value to flashes again.
  • Page 58: Overriding A Lock

    “Pass Code” to override this lock. Congratulations: Your D4200 LCD Station is completely set up and ready for use. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down buttons to enter the to begin entering numbering from zero (0).
  • Page 59: Overview Of Unit Controls

    Scene fades out. Tapping a Scene button twice (if enabled) causes the lighting levels to change Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Enabling the Station Lock Selects a new Scene, and causes a pre...
  • Page 60 Scene Programming or Recall Select Option and Save Menu and Cancel Button Figure 15 - D4200 Buttons Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller buttons, the individual Zone Up Previous/Next Next Field or Menu Option Change Scene Bank Shortcut...
  • Page 61 User Guide Operate the buttons on the D4200 one at a time. If you activate the station lock code or the station lockout switch, the Master Up/Down, Zone Up/Down, SCENE, MAX, and OFF buttons are disabled until a code is entered or the lockout switch is deactivated (see Overriding a Lock Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller...
  • Page 62: Operation

    The OFF button can be modified from the default value of no light (see Levels Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Changing the MAX and OFF Lighting User Guide MAX button OFF button...
  • Page 63 Zones when you press the Master Up Down minimum level, it stays at that level while the other Zones catch up. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller buttons. Once you have recorded Scenes, use buttons. As each Zone reaches its maximum or User Guide...
  • Page 64: Individual Lighting Levels

    MANUAL MODE after any Zone Up button is pressed. You can record these new values for the Scene if you prefer the new lighting levels. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller buttons, adjust the individual lighting levels for or Down User Guide button.
  • Page 65: Checking Zone Names And Lighting Levels

    Just to the right of the “Zxx:” symbol on the 2nd line is a field that is normally blank. If this Zone is excluded from the current scene, a minus sign (“-”) appears in this position. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller User Guide Zone LED Indicator Zone Status Buttons...
  • Page 66: Checking Scene Names

    Press the Select/Save button to record the lighting levels Step 5: and fade time. The LCD display shows representing the Scene you chose. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down buttons beneath the button to select the REC TO SCENE and Down...
  • Page 67: Snapshotting Light Levels From And Entry Station

    Press the Select/Save button to record the lighting levels Step 5: and fade time. The LCD display shows representing the Scene you chose. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller or Down buttons beneath the Up and Down buttons beneath the...
  • Page 68: Using The Optional Remote Control

    Master RAISE/ LOWER, SCENE, MAX and OFF buttons in the same manner as indicated above. The maximum range for the remote control is approximately 30 feet. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller or Down buttons to adjust each...
  • Page 69: Viewing Scheduled Events

    The sequencer causes Scenes to be activated in a timed sequence. The sequence may be programmed to run once or continuously in a loop. The sequence can be activated manually (preset/scene buttons) Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down Scene to...
  • Page 70 LOOP Press the Up Step 4: through the possible Events. Press the Menu/Cancel button to exit this menu. Step 5: Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller and Down Time until next step Event is executed. STOP and Down...
  • Page 71: Appendixa - Setup Tables

    Appendix A - Tables Zone Table - A1 - Zone Labels and Dimmer Channels Form Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Zone Label User Guide Luma-Net Channel Page 66 of 80...
  • Page 72 Scene Accessible from LCD Station: Accessible from Entry Station: Table A2 - Scene Labels and Zone Exclusions Form Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Scene Label User Guide Zones Excluded from Scene Page 67 of 80...
  • Page 73 R esum e, C ell O n, Seq. # ) E vent # Table A3 - Scheduling Form Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller A ction (Scene #, M ax, D ays of the O ff, Seq. O n, Seq. O ff,...
  • Page 74 Delay, Skip, Goto Step, Sequencer Loop, Stop, Off and Delay, Event # Max and Delay Table A4 - Sequencer Form Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Sequencer Event # User Guide Action (Scene # and Delay, Skip, Goto Step, Loop, Stop,...
  • Page 75: Appendixb - Latitude And Longitude Charts

    34° N Jonesboro 36° N Little Rock AP (S) 5° N Pine Bluff AP 34° N Texarkana AP 33° N Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Long. State/City CALIFORNIA 86° W Bakersfield AP 86° W Barstow AP 85° W Blythe AP 87°...
  • Page 76 39° N Wilmington AP 40° N DISTRICT OF COLUMBIA Andrews AFB 38° N Washington, National AP 39° N Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Long. State/City 121° W FLORIDA 118° W Belle Glade 120° W Cape Kennedy AP 122°...
  • Page 77 Columbus, Bakalar AFB 39° N Crawfordsville 40° N Evansville AP 38° N Fort Wayne AP 41° N Goshen AP 42° N Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Long. State/City Hobar 116° W Huntington 114° W Indianapolis AP 117° W Jeffersonville 112°...
  • Page 78 Baltimore Co 39° N Cumberland 40° N Frederick AP 40° N Hagerstown 40° N Salisbury (S) 38° N Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Long. State/City 99° W MASSACHUSETTS 98° W Boston AP 96° W Clinton 97° W...
  • Page 79 49° N Glasgow AP (S) 48° N Glendive 47° N Great Falls AP (S) 47° N Havre 49° N Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Long. State/City 94° W Helena AP 92° W Kalispell AP 93° W Lewiston AP 92°...
  • Page 80 41° N Niagara Falls AP 43° N Olean 42° N Oneonta 43° N Oswego Co 43° N Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Long. State/City 75° W Plattsburg AFB 75° W Poughkeepsie Rochester AP Rome, Griffiss AFB 106° W Schenectady (S) 107°...
  • Page 81 Corvallis (S) 44° N Eugene AP 44° N Grants Pass 42° N Klamath Falls AP 42° N Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Long. State/City 84° W Medford AP (S) 84° W Pendleton AP 84° W Portland AP 83°...
  • Page 82 32° N Fort Worth AP (S) 33° N Galveston AP 29° N Greenville 33° N Harlingen 26° N Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Long. State/City Houston AP 98° W Houston Co 97° W Huntsville 98° W Killeen, Robert Gray AAF 31° N 98°...
  • Page 83 44° N Green Bay AP 44° N La Crosse AP 44° N Madison AP (S) 43° N Manitowoc 44° N Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller Long. State/City 76° W Marinette 78° W Milwaukee AP 77° W Racine 80°...
  • Page 84 Press and hold the Master Down display shows INITIALIZING DEFAULTS. Once is reset to the factory default values. Leviton D4200 LCD Ver 2.0 Architectural Lighting Controller appears on the LCD display, the memory LEVITON User Guide button until the LCD...
  • Page 85: Warranty Information

    F.O.B. factory. Leviton is not responsible for removing or replacing equipment on the job site, and will not honor charges for such work. Leviton will not be responsible for any loss of use time or subsequent damages should any of the...
  • Page 86 NOTES:...
  • Page 87 NOTES:...
  • Page 88 59-25 Little Neck Parkway, Little Neck, NY 11362-2591 Telephone: 1-800-323-8920 • FAX: 1-800-832-9538 Visit Leviton’s Web site at http://www.leviton.com and http://www.nsicorp.com © 2002 Leviton Manufacturing Co., Inc. All Rights Reserved Specifications and Pricing Subject to Change at any time LIT-D4200-00 mod 10/29/02...