WARNINGS
• TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST
THAT THE POWER IS OFF BEFORE WIRING!
• TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, or a load in
excess of the specified rating.
• To be installed and/or used in accordance with electrical codes and regulations.
• If you are not sure about any part of these instructions, consult an electrician.
Features
• Cat. Nos. DOS05 and DVS05 have a sensing angle of 180° and a sensing area of coverage of
30 x 30 ft. See coverage diagram for details.
• Adjustable ambient light (DOS05 only), time delay and area of coverage controls. See adjustment
setting section for details.
• Indicator light alerts the user of device status.
• Adjustable time delay setting for 1, 5, 10 and 20 minutes plus a test mode with 5 seconds on. A
Temporary Bypass mode that disables the Auto-on feature is available only for DOS05.
Mounting Location
The device responds to temperature changes and care should be taken when mounting the device.
•
• DO NOT mount directly above a heat source, in a location where hot or cold drafts will blow directly
on the sensor, or where unintended motion (e.g., hallway traffic) will be within sensor's
field-of-view.
You Will Need:
• Slotted/Phillips screwdriver
• Electrical tape
• Cutters
• Pliers
Installation
WARNING: TO AVOID FIRE, SHOCK OR DEATH, turn off power at circuit breaker or fuse and test
that the power is off before wiring.
1. Identify your wires
(most common):
NOTE: Neutral wire (if present), or a Ground wire is required for operation. If the wiring in the
wall box does not resemble this configuration, consult an electrician.
Single Pole
LINE
GROUND
OR
LOAD
3-Way (Neutral NOT present)
Switch Wallbox
From
To Sensor
Branch Circuit
Wallbox
TRAVELER 1
TRAVELER 2
GROUND
LINE
OR
3-Way (Neutral present)
Switch Wallbox
From
Branch Circuit
LINE
NEUTRAL
GROUND
GROUND
NEUTRAL
TRAVELER 1
TRAVELER 2
To Sensor
Wallbox
NOTE: Sensor must be installed in the location where the load wire is.
Single Pole and 3 Way with 3-Way Switch Application
Wide View Motion Activated Light Control
Cat. Nos. DOS05, DVS05 - INDOOR USE ONLY
Ratings: 120VAC, 60Hz 600 W Incandescent, 5 A Resistive, 300W LED and CFL, 400 VA ELV/MLV, 1/4 HP Motor
LINE
GROUND
NEUTRAL
GROUND
LOAD
Sensor Wallbox
From Switch Wallbox
To Light
TRAVELER 1
TRAVELER 2
LOAD
GROUND
Sensor Wallbox
To Light
LOAD
NEUTRAL
GROUND
GROUND
NEUTRAL
TRAVELER 1
TRAVELER 2
From Switch
Wallbox
CAUTIONS
• To clean use a damp cloth with mild soap. DO NOT use disinfecting products, including foggers, sprays or other
types of atomized cleaning agents.
• No user serviceable components. DO NOT attempt to service or repair.
• Use this device WITH COPPER CLAD WIRE ONLY.
INSTALLATION
2a. Wire (when Neutral is NOT present).
Working on one connection at a time, connect wires as shown.
NOTE: This device is designed so the line and load wires can be wired interchangeably.
Single Pole
TRAVELER
(Red/yellow)
LINE/LOAD
(Black)
GROUND
(Green
sleeved wire)
LINE/LOAD
(Black)
GROUND
(Green/yellow)
3-Way
NOTE: To control the load from the 3-way
switch, toggle once to turn the load ON
and twice to turn the load OFF.
3-Way Switch Wallbox 1
From Branch Circuit
GROUND
(Green)
LOAD
TRAVELER 1
(Red)
TRAVELER 2
LINE
(Black)
2b. Wire (when Neutral is present).
Remove the GREEN sleeve from the white wire. Working on one connection at a time, connect
wires as shown.
NOTE: This device is designed so the line and load wires can be wired interchangeably.
Single Pole
TRAVELER
(Red/yellow)
LINE/LOAD
(Black)
NEUTRAL
(White)
LINE/LOAD
(Black)
GROUND
(Green/yellow)
3-Way
NOTE: To control the load from the 3-way
switch, toggle once to turn the load ON
and twice to turn the load OFF.
3-Way Switch Wallbox
From Branch Circuit
GROUND
(Green)
TRAVELER 1
LOAD
(Red)
TRAVELER 2
LINE
(Black)
3. Test and mount.
• Restore power. Wait 10-20 seconds for sensor to power up.
• DOS05: lights will automatically turn ON with first motion seen after warm up period, or press push
pad.
• DVS05: press push pad. Lights should turn ON.
NOTE: If lights do not turn ON, refer to the "What to do if..." section.
Turn off power at circuit breaker before completing the installation.
• Gently push wires into wall box. Screw light control to box.
• Install wallplate.
• Restore power.
LINE
GROUND
LOAD
Sensor Wallbox 2
TRAVELER
(Red/yellow)
LINE/LOAD
(Black)
GROUND
(Green
sleeved wire)
LINE/LOAD
To Sensor
(Black)
Wallbox 2
GROUND
(Green/Yellow)
LINE
GROUND
NEUTRAL
LINE
GROUND
LOAD
Sensor Wallbox
TRAVELER 1
(Red/yellow)
LINE/LOAD
(Black)
NEUTRAL
(White)
LINE/LOAD
(Black)
GROUND
(Green/Yellow)
LINE
NEUTRAL
GROUND
To Sensor
Wallbox
PK-A3346-10-00-2A-X4
ENGLISH
From 3-Way Switch
To Light
Wallbox 1
TRAVELER 1
LOAD
GROUND
TRAVELER 2
To Light
NEUTRAL
TRAVELER 1
LOAD
GROUND
TRAVELER 2
From 3-Way Switch
Wallbox