INSTALLATION INSTRUCTIONS

WARNING:
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH
APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
WARNING:
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE
INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
WARNING:
DO NOT CONNECT LINE VOLTAGE WIRES TO LOW-VOLTAGE
TERMINALS.
WARNING:
TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE
DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO NOT INSTALL TO
CONTROL A RECEPTACLE.
WARNING:
USE ONLY WITH THE APPROPRIATE ADVANCE
TRANSFORMER MARK 10™ POWERLINE 120V ELECTRONIC DIMMING
BALLASTS FOR CONTROLLING THE SPECIFIC FLUORESCENT LAMPS.
CAUTION:
USE WITH INCANDESCENT: (TUNGSTEN, 120V HALOGEN
FIXTURES), COLD CATHODE, MAGNETIC LOW- VOLTAGE TRANSFORMER
FIXTURES, OR ADVANCE TRANSFORMER MARK 10™ POWERLINE 120V
ELECTRONIC DIMMING BALLASTS ONLY. DO NOT USE THIS PRODUCT TO
CONTROL ELECTRONIC (SOLID STATE) LOW- VOLTAGE TRANSFORMERS.
OTHER CAUTIONS:
1. WHEN A MAGNETIC LOW- VOLTAGE CIRCUIT IS OPERATED AT A DIM
LEVEL, WITH ALL LAMPS INOPERATIVE, EXCESS CURRENT MAY
FLOW THROUGH THE TRANSFORMER. TO AVOID POSSIBLE
TRANSFORMER FAILURE DUE TO OVERCURRENT, USE A
TRANSFORMER THAT INCORPORATES THERMAL PROTECTION OR A
FUSE AT THE PRIMARY WINDINGS.
2. WHEN USING WITH FLUORESCENT BALLASTS, BOTH LIGHTING
FIXTURE AND DIMMER MUST BE PROPERLY GROUNDED.
3. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH
ALUMINUM WIRE USE ONLY DEVICES MARKED CO/ALR OR
CU/AL.
4. DO NOT MIX LOAD TYPES ON A SINGLE ZONE (I.E, 120V TUNGSTEN
AND MAGNETIC LOW-VOLTAGE).
5. DISCONNECT POWER WHEN SERVICING FIXTURES OR CHANGING
LAMPS.
TO INSTALL:
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT
CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE
WIRING!
2. Determine location for installation of the Multizone Controller.
INSTALLATION INSTRUCTIONS
7