Quick Installation Guide V1.0-2022-03-20
Applications
01
Ezlink3000-US is an intelligent wireless data acquisition board compatible with the IEEE2030.5
protocol. It can collect and forward the data of the adapted inverter and transmit bidirectional
encrypted data to the server through the protocol.
The board is connected to the inverter through the 5PIN interface to power itself and
communicate with the inverter. It supports Bluetooth protocol, which allows device
configuration, information reading, local diagnosis, and other functions through Bluetooth
communication. The board also supports WiFi (standard), wired LAN (optional), and 4G
(optional) communication methods, which allows it to communicate with iCloud, the power
company, or a third-party monitoring device to complete data interaction, information query,
and remote diagnosis. Bluetooth and WiFi signals are transmitted via the same internal
integrated antenna, while the 4G signal is transmitted via a separate 4G antenna. The wired
10/100Mbps self-adaptive network port is also optional for wired network needs.
The Ezlink 3000-US board is convenient to operate, making the inverter smart and
interconnected easily.
02
Power On
Step 1 Power on the inverter.
Step 2 Power on the router.
Step 3 Check communication status of the Ezlink through indicators.
Note: Check the indicators on the Ezlink and the inverter to confirm the communication
status of the device.
Indicator/Silkscreen Color
RELOAD
Status
Description
Blink
The Ezlink is working properly.
Blue
OFF
The inverter is powered off.
ON
The Ezlink is connected to the server.
Green
Blink 2
The Ezlink is not connected to the router.
Blink 4
The router is not connect to the internet.
Short press to restart the Ezlink.
Long press for 5 seconds to restore factory settings.
-
-
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Ezlink3000-US and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Goodwe Ezlink3000-US

  • Page 1 Quick Installation Guide V1.0-2022-03-20 Applications Ezlink3000-US is an intelligent wireless data acquisition board compatible with the IEEE2030.5 protocol. It can collect and forward the data of the adapted inverter and transmit bidirectional encrypted data to the server through the protocol.
  • Page 2 Quick Installation Guide V1.0-2022-03-20 Commissioning Commissioning via PV Master App Step 1 Download and install the PV Master App. PV Master App Step 2 Connect the app and the device. Step 3 Set communication settings of the device. • The interface may differ depending on the communication method. •...
  • Page 3 Quick Installation Guide V1.0-2022-03-20 When the RSSI value is less than -60, you should move the router closer to the device, remove the obstacle, or add a repeater to improve the signal strength.
  • Page 4: 04 Troubleshooting

    Quick Installation Guide V1.0-2022-03-20 Name Description • Enable DHCP when the router is in dynamic IP mode. DHCP • Disable DHCP when a switch is used or when the router is in static IP mode. IP Address • Do not configure the parameters when DHCP is enabled. Subnet Mask •...
  • Page 5 WiFi Communication 802.11 b/g/n(2412MHz-2462MHz) Operating temperature range -30 ~ +60°C Storage temperature range -30 ~ +70°C Environment Parameters Relative humidity range 0-100%, No consideration Max. operating altitude <4000m Website GoodWe Technologies Co., Ltd No.90 Zijin Road,suzhou,Jiangsu,China www.goodwe.com service@goodwe.com 340-00647-00 Local Contacts...
  • Page 6 FCC Statement Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
  • Page 7 OEM Guidance Applicable FCC rules This device complies with part 15.247 of the FCC Rules. The specific operational use conditions This module can be used in IoT devices. The input voltage to the module is nominally 5V DC. The operational ambient temperature of the module is -30 °C ~ 60 °C.
  • Page 8 The testing should check for emissions that may occur due to the intermixing of emissions with the other transmitters, digital circuitry, or due to physical properties of the host product (enclosure). This investigation is especially important when integrating multiple modular transmitters where the certification is based on testing each of them in a stand-alone configuration.
  • Page 9 placed in the receive mode or idle mode, if possible. If receive mode only is not possible then, the radio shall be passive (preferred) and/ or active scanning. In these cases, this would need to enable activity on the communication BUS (i.e., PCIe, SDIO, USB) to ensure the unintentional radiator circuitry is enabled.