Fuse and Mains Plug Replacement
This product is supplied with a moulded plug, which contains
a 3A fuse. If you are simply replacing the fuse, you must use
a 3A fuse which has been approved by ASTA to BS1362.
If the plug becomes damaged, a new plug must be fitted.
Replace the original plug with a 13A (BS1363) plug and make
sure that it is fitted with an ASTA approved 3A fuse.
Never use the moulded plug without the fuse cover fitted.
To replace the plug:
1. Cut off the existing fitted plug and dispose of it.
2. The wires in the mains lead supplied with this appliance
are coloured in accordance with the following code:
GREEN/YELLOW = EARTH (E)
BLUE = NEUTRAL (N)
BROWN = LIVE (L)
This product MUST be earthed.
As the colours of the wires in the mains lead may not correspond with the colour markings identifying the terminals
in your new plug, proceed as follows:
The wire which is coloured GREEN or YELLOW/GREEN must be connected to the terminal which is marked with
the letter E or
symbol or a coloured GREEN or YELLOW/GREEN.
The wire which is coloured BLUE must be connected to the terminal in the plug which is marked with the letter N or
coloured BLACK or BLUE.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or
coloured RED or BROWN.
Ensure that the connections are tight and that no loose strands are left out of the terminals.
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN – DO NOT ATTEMPT TO CHANGE THE PLUG
YOURSELF
If the mains lead becomes damaged consult a qualified electrician.
SPECIFICATION
Model Number
Voltage
Moisture Removal
Power Input
Operating Temperature
Noise Rating
Dimensions (H x W x D)
Weight
IG9805
220-240V ~ 50Hz
50 Litres per day (30°C 80% RH)
740W
5°C - 32 °C
55dB
600 x 388 x 282 mm
20 kg
FUSE
Green/Yellow
(Earth)
Blue
(Neutral)
FUSE
COVER
Brown
(Live)
CABLE
GRIP