Toshiba TOSVERT VF-A5 Instruction Manual page 149

High-performance inverter
Hide thumbs Also See for TOSVERT VF-A5:
Table of Contents

Advertisement

Grol4>
Function
Title
Adjustment
range
Resolution
Defaijt
Re-
marlts
Gr.DY
Dynamic braking selection (DBR)
Pb
0: No DBR
-
Depends
Gr.
Pr
Hoist
1: With DBR, no Olr detection
K:>n inverte
2: With DBR, and Olr detection
rating
Overvoltage stall protection
DPSS
O:ON
-
0
Gr. Pr
1: OFF
DC
injection starting frequency
dbF
0-120
0.1/0.01Hz
0.0
Gr. Pr
-----T----------------------
"°dbC---,-:
---------------------------- ---------
Other :
DC
injection current
0-100%/A
1%/A
0
than
: DC
injection time
dbl:
.
0-10
0.1
sec.
0.0
I
0
I
I
Forward/reverse DC injection priority
db
SL
O
:
OFF
-
1
Gr. Pr
control
1:0N
Emergency stop selection
EScP
0: Coast-stop
-
0
Gr. Pr
1 : Decelerated stop
I
g~~~~~~i~~~~-----------
--2---:-Esrff
P"ocirlieciioritime-
_________
..,.
__
----------
------
Edbl=
0-10 sec.
0.1 sec.
0.1
Motor overload protection level
I=:-:.-
I
10-100%/A
1%/A
100
Gr.
Pr
I
OL reduction start-up frequency
DLF
0-30
0.1/0.01 Hz
30.0
Gr.
Pr
OL selection
n1
n
u~••
0:
Standard
-
0
Gr.
Pr
+
1:
Solt-stall ON
+2: OLM! trip OFF
Stall protection
ScC
I
O:ON
-
0
Gr. Pr
I
1: OFF
--o--1s1a1ipr0teciioriievei(current
-s:=r--,-
--
----------------------------
---------
-------
.
10-215%/A
1%/A
150
: limit level adjustment)
Output short-circuit detection
OCLS
0: Standard
-
0
Gr. Pr
selection (OCL)
+ 1 : High-speed motor use
+2:
Positioning use (during JOG)
Fault trip saving
t.-CL
0:
Cleared when powerd OFF
-
0
Gr.
Pr
1:
Data retained when powered
OFF
FM terminal function selection
t=nSL
0-16
-
0
Gr. AM
Refer to the standard parameter
list for details.
Frequency meter adjustment
,en
-
-
-
Gr.AM
AM terminal function selection
.c:nst
0-16
-
3
Gr.AM
Refer to the standard parameter
list for details.
Ammeter adjustment
Rr•
I
I
I
-
-
-
Gr.AM
Number ol motor poles
nc.F'
2,4,
6,8, 10, 12, 14, 16
2
4
Gr.
Mt
Motor rated capacity
ill::.[
0.1-999.9
0.1kW
(Note
1) Gr.
Mt
Motor type
n1::.1=
I
0:
Toshiba standard motor
-
0
Gr.
Mt
I
I
1
:
Toshiba VF motor
I
I
I
2:
Other
I
------..----------------------
~---------1---
--------------------------- ----------
------
2
L~~~-~~l~~Q.~-----------
,-,,_
I
90-600
5V
200/400
I
''-•'-1
I *
~---------r---
--------------------------- ----------
: Rated frequency
r:c.F
, .
0-400
2Hz
60
~----------------------
~---------L.--
---------------------------
---(RPM ___
------
:Rated RPM
ne .. - : .
0-9999
1710
r----------------------
~---------~--
--------------------------- ----------
: Auto-tuning
n1::.c.-. : •
0:
Aul-tuning disabled
-
0
I
I
1
:
Aul-tuning enabled
I
I
Load moment of inertia
r:1=.
II. I
I
,,-,
I
0-3
-
1
Gr. Mt
(Note 1) Same as inverter capacity
-143-

Advertisement

Table of Contents
loading

Table of Contents