Download Print this page

Electrical Box - Daikin RK18NMVJU Removal Procedure

Hide thumbs Also See for RK18NMVJU:

Advertisement

Si001555EA

3. Electrical Box

Warning
Step
1
Remove the 7 screws
on the terminal board
and disconnect the
connecting wire and
power supply wire.
2
Loosen the 2 nuts of the
conduits and remove
the connecting wire and
power supply wire.
3
Remove the 2 screws
and remove the conduit
mounting plate.
4
Remove the 2 screws.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Conduit
Terminal board
Nut
Power
supply
wire
(R21964)
Connecting wire
Conduit
mounting
plate
(R21965)
(R20921)
Electrical Box
Points
When reassembling, fit the 2
hooks of the conduit
mounting plate to the right
side panel.
Right side
panel
Hook
(R21966)
7

Advertisement