Advertisement

Electronic Expansion Valve Coil / Four Way Valve
Step
2
Remove the screw and
remove the four way
valve coil.
3
Remove the terminal
cover.
4
Remove the protection
bushing.
5
Disconnect the
compressor lead wires
and the overload
protector.
20
Procedure
Four way valve coil
Terminal cover
Protection bushing
V (yellow)
Overload
protector
(R21991)
(R21992)
U (red)
W (blue)
(R21993)