Si001355E
2. Outdoor Fan / Fan Motor
Warning
Step
1
Disconnect the
connector [S70].
2
Release the fan
motor lead wire from
the groove of the
partition plate and
the 4 hooks on the
electrical box.
3
Remove the nut and
remove the outdoor fan.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Outdoor fan
[S70]
(R19430)
Hook
(R19431)
Outdoor Fan / Fan Motor
Points
[S70]: fan motor
(R19360)
Nut size: M6
10 mm
(0.39 inch)
(R18954)
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
3