Confirm that the proper services are available. The water supply must be a ½" water line with a
½" threaded ball valve female end. Anything smaller than ½" is not acceptable and should
never be used. The electrical outlet must be within the range of the power cord of the
machine, extension cords should never be used. CO2 is also provided by the customer in either
a tank or with a line from a bulk or remote system. If connecting to an existing system the
customer must provide a ¼" barbed shutoff within 40" of the installation. Check for proper top
and bottom ventilation, drain and countertop holes.
If any of the required services are missing/incorrect or if you have any questions regarding the
commissioning instructions, please call 877-999-1044 option #5, and someone from our Tech
Support Team will provide further instructions.
Open packaging and check for any damage, check that all parts are included by using the
supplied diagram. Do not make any connections yet.
Install the ViTap Font using supplied installation kit.
Connect Water line to street water outlet using supplied kit and diagram.
Fill chiller water tank
Connect street water pipe to the machine and insulate the pipe
on just yet. A minimum water supply of 55psi should be supplied to the machine or
the dispense operation will become slow and may need
a booster pump.
*If installing a Vi1H water connections to the Mavea filter should be made now. Be sure to flush
10 liters of water through the filter before connecting to the boiler. Connect the Mavea filter to
the boiler using the supplied parts and diagram.
vivreauwater.com
1
Tel: 877-999-1044 (Option #5 for Tech Support)
Vi1 and Vi1H
VIVREAU VITAP SYSTEM
COMMISIONING INSTRUCTIONS
Vivreau logo
turn
water

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vi1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vivreau Vi1

  • Page 1 Vi1 and Vi1H VIVREAU VITAP SYSTEM COMMISIONING INSTRUCTIONS Confirm that the proper services are available. The water supply must be a ½” water line with a ½” threaded ball valve female end. Anything smaller than ½” is not acceptable and should never be used.
  • Page 2 Hang provided “Do Not Use” sign on the tap. Remove the 3M filter and fill the service cartridge (located in Vivreau Tech Kit) with 2ml BTF Idopher using the provided syringe (wear safety glasses) and connect to the filter head. Now turn on the water supply.
  • Page 3 Make sure the surfaces are clean, water is taste tested, and all functions are fully tested before training the customer on using the ViTap. Remove “Do Not Use” sign. Make sure to completely fill out the Vivreau Installation Checklist recording all information needed, including the serial number and accurate system location. vivreauwater.com...

This manual is also suitable for:

Vi1h

Table of Contents