Cooling Capacity - Upflow, Downflow & Horizontal Furnaces And Coils (Coil Only Ratings) - Coleman LX Series Technical Manual

Split system air conditioners
Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT MODEL
TCG36B31S
CF/CM/CU36B
TCG36B31S
CF/CM/CU36C
TCG36B31S
CF/CM/CU36D
TCG36B31S
CF/CM/CU42C
TCG36B31S
CF/CM/CU42D
TCG36B31S
CF/CM/CU48C
TCG36B31S
CF/CM/CU48D
TCG36B31S
CF/CM/CU60C
TCG36B31S
CF/CM/CU60D
TCG36B31S
TCG36B41S
CF/CM/CU36B
TCG36B41S
CF/CM/CU36C
TCG36B41S
CF/CM/CU36D
TCG36B41S
CF/CM/CU42C
TCG36B41S
CF/CM/CU42D
TCG36B41S
CF/CM/CU48C
TCG36B41S
CF/CM/CU48D
TCG36B41S
CF/CM/CU60C
TCG36B41S
CF/CM/CU60D
TCG36B41S
TCG48B31S
CF/CM/CU48C
TCG48B31S
CF/CM/CU48D
TCG48B31S
CF/CM/CU60C
TCG48B31S
CF/CM/CU60D
TCG48B31S
CF/CM64D
TCG48B41S
CF/CM/CU48C
TCG48B41S
CF/CM/CU48D
TCG48B41S
CF/CM/CU60C
TCG48B41S
CF/CM/CU60D
TCG48B41S
CF/CM64D
TCG60B31S
CF/CM/CU60C
TCG60B31S
CF/CM/CU60D
TCG60B31S
CF/CM64D
TCG60B41S
CF/CM/CU60C
TCG60B41S
CF/CM/CU60D
TCG60B41S
CF/CM64D
For rated condition information, see the footnotes below the System Capacity - Single Piece and Modular Air Handlers table.
1. Systems matched with furnaces or air handlers not equipped with blower-off delays may require 60 second time delay.
— = Not Applicable.
MP Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
Johnson Controls Ducted Systems
COIL
MODEL
WIDTH
17.5
21
24.5
21
24.5
21
24.5
21
24.5
CF42B
17.5
17.5
21
24.5
21
24.5
21
24.5
21
24.5
CF42B
17.5
21
24.5
21
24.5
24.5
21
24.5
21
24.5
24.5
21
24.5
24.5
21
24.5
24.5
CFM RANGE
RATED
(MIN.-MAX.)
CFM
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1000 - 1400
1200
1400 - 1800
1500
1400 - 1800
1500
1400 - 1800
1500
1400 - 1800
1500
1400 - 1800
1500
1400 - 1800
1500
1400 - 1800
1500
1400 - 1800
1500
1400 - 1800
1500
1400 - 1800
1500
1520 - 1920
1725
1520 - 1920
1725
1520 - 1920
1725
1520 - 1920
1725
1520 - 1920
1725
1520 - 1920
1725
5562621-CTG-C-0320
COOLING
NET MBH
SEER
TOTAL
SENS.
34.6
25.6
14.50
34.6
25.6
14.50
34.6
25.6
14.50
35.4
25.6
15.00
35.4
25.6
15.00
36.0
26.2
15.50
36.0
26.4
15.25
36.0
26.0
15.25
36.0
26.0
15.25
35.4
25.6
15.00
34.6
25.2
14.50
34.6
25.2
14.50
34.6
25.2
14.50
35.4
25.6
15.00
35.4
25.6
15.00
36.0
26.4
15.50
36.0
26.4
15.25
36.0
26.0
15.25
36.0
26.0
15.25
35.4
25.6
15.00
45.0
32.6
14.75
45.0
32.6
14.75
45.5
33.0
15.50
46.0
33.4
15.25
47.0
33.8
15.50
45.0
32.4
14.75
45.0
32.4
14.75
45.5
33.0
15.50
46.0
33.4
15.25
47.0
34.0
15.50
56.5
40.0
14.50
56.5
40.0
14.50
57.5
40.5
15.00
56.5
40.0
14.50
56.5
40.0
14.50
57.5
40.5
15.00
1
EER
12.50
12.50
12.50
12.50
12.50
12.75
12.75
12.75
12.75
12.50
12.50
12.50
12.50
12.50
12.50
12.75
12.75
12.75
12.75
12.50
12.25
12.25
12.75
12.75
13.00
12.25
12.25
12.75
12.75
13.00
12.00
12.00
12.75
12.00
12.00
12.75