Duevi EZY-LAN HW 3B Installer Manual

Wireless alarm panel with ethernet + wi-fi + gsm + lte

Advertisement

Quick Links

EZY-LAN Wireless alarm panel with Ethernet + Wi-Fi + GSM + LTE
1
Identification of the parts
FRONTAL VIEW
1 – led power
2 – led Ethernet
3 – led Wi-Fi
12
8
BOTTOM VIEW VERSION HW 3B
12
8
BOTTOM VIEW VERSION HW 4A/4B
8 – button PWR
9 – button RJ45
10 – nanoSIM housing
4 – led GSM + LTE
5 – programmable central button
6 – multicolor led ring
10
9
11
9
10
11
11 – power supply input 12Vdc
12 –button PRT (internal)
EZY-LAN 22.07-M:3.1-H:3b/4a/4b-F:3.3.4+
2
Wall mounting
The control panel is equipped with a wall
mounting bracket, which also integrates the
housing for the anti-removal tamper magnet.
1
2
3
PLEASE NOTE
4
The anti-removal tamper function is
available starting from the HW 4B version
5
6
13
14
To mount, proceed as follows:
1. Use the bracket as a template for the holes
2. Drill two 5mm diameter holes on the wall at the
points (13)
3. (IF TAMPER PROTECTION NECESSARY)
Make a 6mm diameter hole 20mm deep on the
wall at point (15)
4. Fix the wall bracket with the supplied plugs
through the holes (13)
5. (IF TAMPER PROTECTION NECESSARY)
Insert the magnet supplied in the appropriate
hole in the bracket (15)
6. Insert the control panel on the bracket
matching the slots on the bottom with the
appropriate supports (14), then move the
control panel downwards until it stops.
13 - holes for wall plugs
14 – control panel supports
15 - hole for magnet (optional)
13
15
14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EZY-LAN HW 3B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Duevi EZY-LAN HW 3B

  • Page 1 EZY-LAN 22.07-M:3.1-H:3b/4a/4b-F:3.3.4+ EZY-LAN Wireless alarm panel with Ethernet + Wi-Fi + GSM + LTE Identification of the parts Wall mounting The control panel is equipped with a wall mounting bracket, which also integrates the housing for the anti-removal tamper magnet. PLEASE NOTE The anti-removal tamper function is available starting from the HW 4B version...
  • Page 2: Power Supply And Battery

    LED signals Power supply and battery The system status indication of the RGB LEDs (6) The control panel is powered by an external can be disabled in the programming. 12Vdc 2Ampere power supply to be connected to The intensity of the RGB LEDs (6) is reduced after the appropriate jack input (11).
  • Page 3: Manual Settings

    RED = function disabled connect a network cable, simply connect the 4. To change the function setting, briefly press device on which the DUEVI Connect app is the central button (5) installed directly to the WIFi of the control panel 5.
  • Page 4 • 11.2 Connections Power – Indications on the power supply and battery of the control panel PRIORITY OF CONNECTIONS The homepage also contains two buttons: Ethernet is the primary channel that is used • ENTER SETUP – Allows to enter the setup if a network cable is connected.
  • Page 5: Control Panel

    Contact, Vibration, External Contact, Shutter), a Voice message recording MINI-M contains a zone (Contact), etc Within the GSM section, press the icon (gear) PLEASE NOTE: The keyfob is not to access the page where you can manage the considered a device, but must be added voice message (maximum duration 60 seconds) within the individual user.
  • Page 6 • • Wireless supervision: enables / disables the Visual and sound signals for: Alarm L1, Panic device presence control alarm, Arming, Disarming, System status • Masking control: enable / disable the device 12.1.2 IP Devices (Shelly) masking control • Individual zone setting: It is possible to add and manage Shelly devices Zone name (produced by Allterco Robotics LTD).
  • Page 7: Outputs Management

    The control panel will communicate with the The SECTORS page contains the list of all Shelly, identify its model, firmware, mode, input created sectors (two sectors are already present by default: “Perimetrali” and “Volumetrici”). zones, outputs and will add it to the device list of the control panel.
  • Page 8: Notifications (Setup)

    • Administrator [user with extended Action Name: is the name with which the privileges, can enable installer, can modify Action is identified in all menus, notifications, notifications, etc], events, etc. • Normal [user with reduced privileges], Type of Action: ✓ Arming Police [user limited to the telephone number to call in case of alarm] Operation on Sectors: No change [the...
  • Page 9 The PROGRAMS page contains the list of all time Pressing the icon (info) expands the display of programs created. the related notifications. Active notifications are colored in blue. Pressing the icon (trash can) deletes the program. Events included in the various categories: Pressing the icon (gear) you enter the program •...
  • Page 10 • • Alarm zones: up to 4 zones which, following Triggering event: represents the event that an alarm, generate the image capture triggers execution defined operations. following settings 12.8 Scenarios (SETUP) available for this event: Sector event: A Scenario is a list of Actions (maximum 16) that Alarm L1 in sectors (OR logic) the control panel carries out in sequence with a Alarm L2 in sectors (OR logic)
  • Page 11 • 13 Homepage (TEST) Client Account: client identification code - provided by the Monitoring Station By pressing the ENTER TEST button, the control • Server IP address: IP address of the receiver panel switches to test mode and the RGB LEDs - provided by the Monitoring Station of the control unit flash blue.
  • Page 12: Warnings And Precautions

    EU DECLARATION OF CONFORMITY Hereby, DUEVI declares that the radio equipment type “Wireless alarm control panel with Ethernet / Wi-Fi / GSM / LTE connection” mod. EZY-LAN is in compliance with Directive RED 2014/53/EU.

This manual is also suitable for:

Ezy-lan hw 4aEzy-lan hw 4b

Table of Contents