PEPEROSSO Dissuader with nebulization irritating gas 14.09-M1.2.1-H1.0-F>1.0-ENG Installation and use manual Made in Italy...
Page 2
INSTRUCTIONS OF THIS MANUAL AND THE LAW REGARDING ELECTRICAL SYSTEMS. Legal notes THE ACTIVE PRINCIPLE USED BY PEPEROSSO IS A NATURAL ESSENCE OF CHILLI PEPPER CALLED OLEORESIN CAPSICUM (OC) WITH A CONCENTRATION OF 10%. THE IMPORTANCE OF THE NATURAL ESSENCE IS THAT IT IS LEGAL AND SAFE: FEW ILLEGAL PRODUCTS EXIST, IN FACT, WITH ACTIVE PRINCIPLES OF CHEMICAL DERIVATION, THAT IN ITALY ARE CONSIDERED “CHEMICAL AGGRESSIVE”...
Introduction Peperosso is a dissuading system with nebulization of irritating gas able to saturate in only 10 seconds an area of 100 m (note: unique environment). The nebulized gas is a no- greasy chilli pepper based gas that causes irritation on skin and mucosa, cough, lacrimation, heavy abundance of mucus and intense burning sensation, persuading the intruder to leave immediately the area.
…IN CASE OF ALARM NEBULISATION IS READY… When the system is in alarm the control panel signals it to Peperosso (input IN2) that prepares nebulisation: the gas is not yet emitted, depends on input IN3 state …AN INTRUDER CAUSE NEBULISATION TO START ...
PEPEROSSO IS ACTIVATED AT CONTROL PANEL ARMING (COMMAND CONNECTED TO INPUT IN1): USE ONLY TOTAL ARMING COMMAND. DO NOT ACTIVATE PEPEROSSO WHEN IN PARTIAL ARMING BECAUSE IS NOT GUARANTEED THE COMPLETE ABSENCE OF PEOPLE IN PROTECTED AREA DO NOT INSTALL THE DEVICE WHEN IN PRESENCE OF NOT PACKAGED FOOD OR ENVIRONMENT INCOMPATIBLE WITH GAS NEBULISATION.
Installation To open the cover unscrew the screws at both sides of the device (fig. 1). Screw for Screw for Cover motor base motor base Motor base Screw Screw Space for spray cans connector (removable) Nebulisation Anti-opening Screw for windows tamper motor base Fig.
Fix the main case on wall using it as template for holes (fig. 3) Peperosso must be fixed stably on a solid vertical wall, with appropriate dowels, in such a way that the spray jet is as much as possible in the direction of any intruders...
Page 10
Press K1 button until the plunger back to its initial position Block Peperosso using IN1 (provide a positive 12 V) Remove jumpers JP1 e JP2 (in this way both tamper of Peperosso are activated) At this point make a functioning test using the test spray can (containing water, see “Test”...
Outputs 1 output for power supply 12 V / 500 mA (2 A for 100 ms MAX) 1 output for failure of Peperosso 1 output for nebulisation occurred Functioning Gas nebulisation can occur only when system is armed (IN1 unlocked) and...
If OUT D is at GND it is necessary to check the power voltages are correct (between 12 and 13,8 ); if power voltages are correct but output D – with Peperosso unlocked – is still at GND, it is necessary to call technical service assistance...
CN11 NOT USED CN12 NOT USED Battery connector 12 V / 0,8 Ah JUMPERS Anti-opening Tamper active Anti-opening Tamper deactivate Anti-removal Tamper active Anti-removal Tamper deactivate BUTTONS Plunger return button (after nebulisation) Allow to – after nebulisation occurred – rearm the device LEDS Normal functioning Battery poles inverted...
At this point make a functioning test using the test spray can (containing water, see “Test” paragraph) At the end of test block Peperosso using IN1 (provide a positive 12 V) Peperosso must stay at rest with the plunger completely back and settled Only in this position is possible to fix the spray cans with the straps (fig.
Deactivate the control panel (IN1 and IN2 to +12 V ) with tamper control excluded, then remove the cover of Peperosso Enable Peperosso removing the positive +12 V from IN1 Press the K1 button to bring the plunger to rest...
(do not provoke the confirm detector connected to input IN3) if Peperosso is connected in Instantaneous mode, the nebulisation of spray (with water) starts immediately if is connected in Driven mode, provoke the confirm detector connected to IN3: Peperosso...
Stand-alone mode Principle diagram for use of Peperosso in stand-alone mode (no control panel required). Hardware key Peperosso Detector Close IN1 and IN2 Must be powered with Connect to Peperosso towards +12 V 12 V on IN3 as confirm disabling Peperosso...