Flow control cleaning / replacement procedure (9 pages)
Summary of Contents for Lance-Larkin Brew Express BE-104C
Page 1
XPRESS ® INSTALLAT ION GUIDE BE-104R & BE-104C model # For more information see our instructional video online at www.BrewExpress.com. Note - BE- 1 04R shown in illustrations.
SAfETy IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed, including the following: 1. Read all Instructions. 2. Do not touch hot surfaces. Use handles or knobs. 3. The voltage and frequency of the supply connections should conform to those of the rating label. 4.
SAfETy IMPORTANT: Read and follow instructions carefully before installing your BREW EXPRESS in-the-wall COFFEE SYSTEM. FOR BEST RESULTS, IT IS ADVISED THAT YOU HIRE A QUALIFIED PROFESSIONAL. Always turn off all power at main electrical panel before attempting to install BREW EXPRESS. Improper electrical wiring could cause a fire hazard.
GET TING STARTED IMPORTANT: Read and follow instructions carefully before installing your BREW EXPRESS in-the-wall COFFEE SYSTEM. For best results, it is advised that you hire a qualified professional. Getting Started Carefully unpack BREW EXPRESS from gift box. Remove carafe and brew basket from brewing unit. If brewer includes carafe lock, press on lever to remove carafe.
HARDWARE BREW EXPRESS comes supplied with the following items to ensure a successful installation. Check to be certain all items have been included with your brewer. • (1) Brewer (with short water line attached to connect with incoming water line) •...
SpECIfICATIONS AND REqUIREmENTS IMPORTANT: Read and follow instructions carefully before installing your BREW EXPRESS in-the-wall COFFEE SYSTEM. For best results, it is advised that you hire a qualified professional. Overall Dimensions (Finished Unit with Rough-in-Box) approximately 9.9” x 11.8” (see below). Dimensions for Rough-in-Box (Mounting Structure) approximately 8.5”...
LOCATION (Area of Installation) The BREW EXPRESS can be installed in most places where power and water are supplied. If only power is available, you may consider using a water bottle and pump. The most common locations are the kitchen, master bathroom or office. Installation inside an exterior wall is not recommended due to risk of water freezing.
wATER INSTALLATION Always turn off water supply at source. It is strongly advised you consult a qualified professional plumber when attempting to install the BREW EXPRESS in-the-wall COFFEE SYSTEM. It is important to make sure there are no conflicts or obstructions in the wall cavity such as plumbing or electrical wires.
Always turn off power supply at main electrical panel before attempting any electrical installation. Local electrical codes vary. All electrical installation must be done in accordance with local codes. Installation must be performed by a qualified electrician, or equivalent. IMPORTANT: Installation must be performed by a qualified electrician, or equivalent.
BREwER INSTALLATION IMPORTANT: If installing unit PRIOR to cabinets, it is strongly advised to consult with cabinet maker and build- ing contractor for exact height of counter top due to the various thicknesses of counter tops (tile laminate, granite, etc). For best results cut hole and install unit AFTER cabinets are installed. A.
Page 13
Installation of Rough-In-Box Locate wall studs adjacent to the desired location. Place template on wall as shown. Outside edge of slots in template should be even with left or right side of stud edge. The slots in the template designate the area to be cut. Outside edge of template is equivalent to brewer size .
Page 14
BREwER INSTALLATION Place rough-in-box on a towel or cardboard to protect counter surface. Bring power supply wire from source to cut opening as shown in Figure 4. Minimum 12-2 wire required. Be sure to have an additional length of approximately 18” at rough-in-box opening for installation of box.
Page 15
The male quick connector has a built in valve so water can be turned on prior to connection to coffee maker. Place unit on a towel or cardboard to protect counter surface. Place BREW EXPRESS directly in front of rough-in box.
BREwER INSTALLATION & TESTING Gently slide the BREW EXPRESS into the rough-in-box. Be careful not to damage water supply lines. A firm push will connect power from rough-in-box to the BREW EXPRESS. Use two mounting screws to secure BREW EXPRESS to rough-in-box.
Button icon is not illuminated • Ensure the power to the rough-in box is turned on (check circuit breaker). • Ensure brewer is fully pressed into the rough-in box. • Ensure the outlet inside the rough-in box is properly wired. Remove the brewer and check outlet with volt meter.
Page 18
TROUBLESHOOTING Water overflow from brew basket • Paper filter is not high enough and grounds are flowing over and plugging brew basket (use higher filter). • Coffee grounds are too fine, use courser grind of coffee. Excessive Steam • Inlet water line connected to hot water supply (connect to cold water). •...
• Check volume of water by running a full cycle of water without coffee. If carafe overfills call for technical service. • Check voltage to coffee maker. Water leak from back of brewer • Check quick connect (push connectors together firmly and slightly twist) •...