Appendix; Failure Monitoring - W.E.ST. PQ-132-U Technical Documentation Manual

P/q-controller, pressure limiting controller for hydraulic axes
Table of Contents

Advertisement

6 Appendix

6.2 Failure monitoring

Following possible error sources are monitored continuously when SENS = ON/AUTO:
Source
Command signal PIN 10
4... 20 mA
Command signal PIN 6
4... 20 mA
Feedback signal PIN 13
4... 20 mA
Feedback signal PIN 14
4... 20 mA
EEPROM
(when switching on)
CAUTION: Take care of the EOUT command. Changes will influence the behavior.
Page 31 of 34
Fault
Out of range or broken wire
Out of range or broken wire
Out of range or broken wire
Out of range or broken wire
Data error
PQ-132-U
Characteristic
The output will be switched off.
The output will be switched off.
The output will be switched off.
The output will be switched off.
The output is deactivated.
The module can only be acti-
vated by saving the parameters
again!