Parameters; Parameter Overview - W.E.ST. PQ-132-U Technical Documentation Manual

P/q-controller, pressure limiting controller for hydraulic axes
Table of Contents

Advertisement

5 Parameters

5.2 Parameter overview

Group
Command
Basic parameter
LG
MODE
SENS
PIN:5
CDWIN
EOUT
Input signal adaption
SYS_RANGE
ARATIO
PRESET:Q
F_OFFSET
Sensor scaling X1
SIGNAL:X1
N_RANGE:X1
OFFSET:X1
Sensor scaling X2
SIGNAL:X2
N_RANGE:X2
OFFSET:X2
Command signal scaling
SIGNAL:W
SIGNAL:Q
Page 19 of 34
Default
Unit
EN
-
STD
-
ON
-
RAMP
-
2000
mbar
0
0,01 %
100
bar
1000
-
0
0,01 %
0
mbar
U0-10
-
100
bar
0
mbar
U0-10
-
100
bar
0
Mbar
U0-10
-
U+-10
-
PQ-132-U
Description
Changing language help texts
Parameter view
Malfunction monitor
Function of PIN 5
Size of the control deviation window
Output signal if not ready
System pressure
Area ratio of the cylinder
Internal preset value
Offset (force), is added to the actual value
Type of input
Sensor nominal pressure
Sensor offset
Type of input
Sensor nominal pressure
Sensor offset
Type of input
Type of input
05.06.2020

Advertisement

Table of Contents
loading