Kongsberg Maritime disclaims any responsibility for damage or injury caused by improper installation, use or maintenance of the equipment. Disclaimer Kongsberg Maritime AS endeavours to ensure that all information in this document is correct and fairly stated, but does not accept liability for any errors or omissions. Support information If you require maintenance or repair, contact Kongsberg Maritime’s...
Instruction Manual Table of contents ABOUT THIS MANUAL .............. 5 CNODE MODEM MINIS LF ............6 System description ......................7 Naming description......................7 System units ........................8 Modems ........................8 Battery charger ......................8 TTC 10 (Transponder Test and Configuration unit)..........8 Support information ......................9 GENERAL ACOUSTIC CONSIDERATIONS ........ 10 GETTING STARTED ..............
Page 4
cNODE Modem MiniS LF ON/OFF plug spare part ....................33 Configuration or power cable spare part................34 Modem cable spare part ....................34 Floating collar spare part ....................34 Transducer guard spare part.....................35 TTC 10 spare part ......................35 Test and configuration cable (TTC to Modem MiniS) spare part........35 Test and configuration cable (PC to Modem MiniS) spare part........35 DRAWING FILE..............
Microsoft Corporation in the United States and other countries. HiPAP ® is a registered trademark of Kongsberg Maritime AS in Norway and other countries. ® cNODE is a registered trademark of Kongsberg Maritime AS in Norway and other countries.
Data rates of up to 6 kb/s are available. One cNODE Modem can address several other cNODE Modems during operation using the Kongsberg Link User Protocol. The modem is simple to configure with the TTC Light software.
The transponder test and configuration unit is designed for on deck testing and configuration of the transponders. The TTC can test all Kongsberg modem low frequency channels, Cymbal and FSK. It can also test telemetry modems with internal and external sensors.
Should you need technical support for your cNODE Modem MiniS LF system you must contact a Kongsberg Maritime office. A list of all our offices is available on our website. You can also contact our main support office in Norway.
cNODE Modem MiniS LF Instruction Manual General acoustic considerations Take this information into consideration when deploying the modems. Acoustic range The term depth rating should not be confused with the term acoustic range. The acoustic range is dependent on many factors, and some of the factors are outside the control of the user.
Page 11
General acoustic considerations Sound velocity and ray bending Variations in water temperature affects the velocity of sound through the water column, and variations in the ocean’s salinity level can bend the acoustic signal making it impossible for the signal to reach the vessel. 110-0000612/A...
Getting started Turning on the modem The modem is designed for operation in water only. The modem may be operated in air for test purposes over a short period of time. Prerequisites The modem must be charged before use. Procedure Grease the connector with Molykote 44 Medium or equivalent grease.
cNODE Modem MiniS LF Instruction Manual Turning on the TTC Use the Transponder Test and Configuration unit to check that the modem is ready for use. Procedure Open the suitcase. Turn on the main power switch to start the program. This takes approximately 1.5 minutes.
Getting started Procedure Make sure the locking cord is in place. If the unit has been altered from the factory pre-sets, check that the unit is configured according to your requirements. Make sure the battery is fully charged. Push the pressure relief valve in to confirm that it is flush with the end cap. Switch the modem ON by inserting the on/off plug.
cNODE Modem MiniS LF Instruction Manual Recovering the modem It is important to perform these recovery checks after every operation. Procedure Wash the unit thoroughly in warm fresh water to dissolve any salt deposits and clean off any sand or silt. As an extra precaution, it is recommended that the unit is left to soak in fresh water to allow salt to dissolve and diffuse from hard-to-reach areas, such as crevices between mating parts.
Cabling Cabling Topics Configuration or power connector pinout, page 18 Connecting the modem to external power and responder signals, page 19 Modem connector pinout, page 20 Connecting the modem to a RS-232 signal, page 22 Connecting the modem to a RS-422 signal, page 23 Connecting the modem to a RS-485 signal, page 24 110-0000612/A...
cNODE Modem MiniS LF Instruction Manual Configuration or power connector pinout The external connector is for configuration, responder function, on/off function and charging. This is the pin configuration for a male connector, as seen towards the connector (face view). Pin 1, 2 and 3 is for configuration. Pin 4 and 5 is for responder function.
External power(24 VDC) Ground Procedure Use the cable with part number 402462 from Kongsberg. Connect wire 6 and 8 in the pigtail (the ON/OFF function). When 6-8 are linked, the modem is ON. With no connection between 6-8, the modem is OFF.
cNODE Modem MiniS LF Instruction Manual Modem connector pinout This is the pin configuration for a female plug, as seen towards the plug (face view). Pin number Signal RS-232 Tx RS-232 Rx Ground RS-422 Tx + RS-422 Tx – RS-422 Rx + RS-422 Rx –...
RS-232 Tx RS-232 Rx Ground Procedure Use the cable with part number 427240 from Kongsberg. Connect wire 1 to the user RS-232 Rx. Connect wire 2 to the user RS-232 Tx. Connect wire 3 to the user RS-232 Ground. 110-0000612/A...
RS-422 Rx + RS-422 Rx – Ground Procedure Use the cable with part number 427240 from Kongsberg. Connect wire 4 to the user RS-422 Rx+. Connect wire 5 to the user RS-422 Rx-. Connect wire 6 to the user RS-422 Tx+.
RS-422 Rx + RS-422 Rx – Ground Procedure Use the cable with part number 427240 from Kongsberg. Connect wires 4 and 6. Connect this wire to the user Tx+/Rx+. Connect wires 5 and 7. Connect this wire to the user Tx-/Rx-.
Operating procedures Operating procedures The modem is operated from the HiPAP operator station APOS. • Refer to APOS online help for descriptions. 110-0000612/A...
Resetting the valve can in certain cases be obstructed due to production of acids and salts leaking from a damaged battery. In such cases the battery and circuits may have been damaged. Please contact Kongsberg Maritime for assistance. Handling a transponder with an open relief valve or heated body If the modem body is hot when recovered, place the modem fully submerged in a bucket of water for 24 hours or deploy into the sea permanently.
cNODE Modem MiniS LF Instruction Manual Caution Equalize the temperature of the cNODE Modem MiniS LF to between 10 °C and 40 °C before charging it. For on-deck charging, use the cNODE battery charger only. Never charge the battery unattended. Procedure Switch off the cNODE Modem.
Maintenance Procedure Demate the connector set. Flush connector interface with fresh water (deionized water if available), remove all dirt, grit and grease. Inspect for damage in sealing areas, excessive corrosion, debonding of the cable and connector interface and cuts in the cable jacket. Apply thin film of dilectric compound (DC) grease, silicon based, to sealing areas of male connector and across the face of the female connector.
Page 30
cNODE Modem MiniS LF Instruction Manual Cut the Molex plug. Use a wrench to remove the connector. Use a wrench with a slim 20 mm socket. The outer diameter of the socket should be 24 mm or less to avoid damaging the transponder housing. Clean the threads in the transponder housing.
If the LED indicator is still • Charger might be faulty flashing red: Charger might be faulty Contact your local Kongsberg Maritime office. Steady red • The battery temperature • Let the unit warm up or might be outside the charging...
Spare parts Ordering spare parts To make the order process as short and efficient as possible, you must provide accurate information about the product, the part you need, and yourself. The following information must be provided with your order: • Part name and/or description •...
cNODE Modem MiniS LF Instruction Manual Configuration or power cable spare part • : Pigtail cable with locking sleeve Part name • : 408094 Part number Modem cable spare part • : Pigtail cable with locking sleeve Part name • : 427240 Part number Floating collar spare part...
Spare parts Transducer guard spare part • : Transducer guard Part name • : 439442 Part number TTC 10 spare part • : TTC 10 (Transponder Test and Configuration unit) Part name • : 463018 Part number Test and configuration cable (TTC to Modem MiniS) spare part •...
Technical specifications Performance specifications These performance specifications summarize the main functional and operational characteristics of the system. • : 12 kHz Operating frequency • : 5 - 25 V positive logic pulse (2 - 6 ms) Responder trigger signal • : Seacon MCBH8MDO Configuration or power connector •...
Technical specifications Power requirements These power characteristics summarize the supply power requirements for the system. Battery • : Li-Ion (LiFePO Battery type • : 58 Wh Nominal capacity Battery charger • : 115/230 VAC 50–60 Hz maximum 1.4 A Input voltage •...
cNODE Modem MiniS LF Instruction Manual • External fire: Internal pressure and thermal runaway may be the consequences if the cells inside the battery are exposed to temperatures above 85 °C. • Internal short circuit: Internal short circuit in a cell. Destruction of the separator can cause a short circuit between the anode and cathode.
Battery safety • : The chemicals are skin irritant. Rinse immediately with a lot of water Skin contact and soap for at least 15 minutes. Wipe immediately away excess material with waterless hand cleaner. Remove contaminated clothing and wash it thoroughly before reuse.
cNODE Modem MiniS LF Instruction Manual Prevent material from contaminating soil and from entering sewers or waterways. Stop the leak if safe to do so. Contain the spilled liquid with dry sand or earth. Clean up the spills immediately. Absorb spilled material with an inert absorbent (dry sand or earth). Scoop contaminated absorbent into an acceptable waste container.
Battery safety SECTION 9: Physical and chemical properties The battery is solid with a hard surface. There is no risk for exposure to the chemicals inside an undamaged battery during normal operation and transportation. The battery is a solid and sealed unit. The battery cannot be opened to reveal the individual cells.
cNODE Modem MiniS LF Instruction Manual SECTION 13: Disposal considerations Adhere to applicable laws, regulations and guidelines when disposing of the batteries. A lithium thionyl chloride battery does not contain any heavy metals, and is therefore not regarded as special waste (it contains only biodegradable parts). A used lithium battery can contain a significant amount of residual energy.
Battery safety Note Damaged transponders that are returned to the manufacturer for repair must be transported without batteries. Damaged or spent batteries that have been recalled by the manufacturer for safety reasons must not be transported by air. SECTION 15: Regulatory information Not applicable.
Page 52
cNODE Modem MiniS LF Instruction Manual Index 401633 dimensions on/off plug ..........33 technical specifications........42 404199 battery charger ........... 33 ecological information battery safety ..........49 about environmental acoustic considerations........10 requirements ..........43 acoustic range ..........10 exposure controls document downloads ........
Page 53
Index description ..........7 safety features pressure relief valve ........27 sensors offices interface specifications ........16 support ............. 9 size technical support .......... 9 technical specifications........42 on/off plug spare part 401633 ............ 33 battery charger ........... 33 spare part..........33 on/off plug ..........