Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service proce-
dures or services performed by an unqualified person.
®
is a registered trademark of Maytag Corporation or its related companies and is used under license
to Goodman Company, L.P., Houston, TX. All rights reserved.
TECHNICAL MANU
TECHNICAL MANU
TECHNICAL MANU AL
TECHNICAL MANU
TECHNICAL MANU
ASX 18 SEER
Condensing Units
Copyright © 2006-2007, 2009, 2011
Goodman Company, L.P.
AL
AL
AL
AL
RT6114003r2
March 2011

Advertisement

loading
Need help?

Need help?

Do you have a question about the ASX 18 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Amana ASX 18 Series

  • Page 1 TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU AL TECHNICAL MANU ASX 18 SEER Condensing Units • Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. •...
  • Page 2: Product Identification

    PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. BRAND: MINOR A: Amana® REVISION: Brand A: Initial Release SEER: MAJOR SEER Rating REVISION: A: Initial Release PRODUCT NOMINAL...
  • Page 3 PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. ASX180361A* ASX180361B* ASX180481A* ASX180481B* ASX180601A* ASX180601B* * Indicates minor revision & is not used for order entry or inventory management The United States Environmental Protection Agency (“EPA”) has issued various regulations re- WARNING WARNING...
  • Page 4: Product Design

    PRODUCT DESIGN ASX18 models are available in 3 4 and 5 ton sizes and use This unit is for outdoor installation only. Refer to minimum R-410A refrigerant. They are designed for 208/230 volt single figure for clearances from the sides of the unit to full walls and other objects.
  • Page 5: Condensing Unit Specifications

    CONDENSING UNIT SPECIFICATIONS ASX180361* - ASX180601* Cooling Capacity, BTUH 36,000 48,000 60,000 Compressor R.L. Amps 16.7 21.2 25.6 L.R. Amps 82.0 96.0 118.0 Low Pressure Switch Open 22 + / - 7 PSIG 22 + / - 7 PSIG 22 + / - 7 PSIG Close 50 + / - 7 PSIG 50 + / - 7 PSIG...
  • Page 6 ASX180361*-LOW STAGE PERFORMANCE DATA...
  • Page 7 PERFORMANCE DATA ASX180361*-LOW STAGE...
  • Page 8 ASX180481*-LOW STAGE PERFORMANCE DATA...
  • Page 9 PERFORMANCE DATA ASX180481*-LOW STAGE...
  • Page 10 ASX180601*-LOW STAGE PERFORMANCE DATA...
  • Page 11 PERFORMANCE DATA ASX180601*-LOW STAGE...
  • Page 12 COOLING PERFORMANCE DATA ASX180361*-HIGH STAGE...
  • Page 13 COOLING PERFORMANCE DATA ASX180361*-HIGH STAGE...
  • Page 14 COOLING PERFORMANCE DATA ASX180481*-HIGH STAGE...
  • Page 15 COOLING PERFORMANCE DATA ASX180481*-HIGH STAGE...
  • Page 16 COOLING PERFORMANCE DATA ASX180601*-HIGH STAGE...
  • Page 17 COOLING PERFORMANCE DATA ASX180601*-HIGH STAGE...
  • Page 18 PERFORMANCE DATA LOW STAGE ASX180361* - ASX180601* ASX180361A* / CA*F4961*6** + TXV / MBE2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5-7°F @ the Serv. Vlv. - Low Stage Outdoor Total Sensible Latent Total Temp. ° F. Btuh Btuh Btuh Watts 75°...
  • Page 19 PERFORMANCE DATA HIGH STAGE ASX180361* - ASX180601* ASX180361A* / CA*F4961*6** + TXV / MBE2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5-7°F @ the Serv. Vlv. - High Stage Outdoor Total Sensible Latent Total Temp. ° F. Btuh Btuh Btuh Watts 75°...
  • Page 20: Wiring Diagrams

    WIRING DIAGRAMS ASX180[36-60]1A* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 21 WIRING DIAGRAMS ASX180[36-60]1B* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.