Technical Data

Angle accuracy of the laser lines
Precision of the vertical laser lines + 0,5 mm / 1 m
Operating range (depending on
room illumination)
Power supply
laser wavelength
Laser class
Weight
Operating temperature
Storage temperature
Order number
Subject to technical changes
without notice
Note:
Regularly check the calibration before use, after
transport and after extended periods of storage.
Checking the vertical line:
Fix a plumb bob with a line at least 2.5 m in length on
the wall, making sure that the bob can swing freely.
Align the spirit levels, turn on the unit, adjust the lines to
the plumb and the spirit-levels (2) with the levelling feet
(6, 7). The precision is within tolerance if the deviation
between the laser line and plumb line is not greater than
0.5 mm / 1 m.
Service- and Shipping Address:
Umarex GmbH & Co KG – Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
laserliner@umarex.com
SuperSquare-Laser
ENGLISH
+ 0,05°
20 m
2 x 1,5V AA / 24 h
635 nm
2M / < 5 mW
0,4 kg
0°C ... + 50°C
-10°C ... + 70°C
081.130A
12/2006