Mitsubishi PWFY-P100VM-E2-AU Data Book page 13

Table of Contents

Advertisement

(3) PWFY-P200VM-E1-AU
Model
Power source
Heating capacity
(Nominal)
Power input
Current input
for outdoor unit
Temp. range of
heating
for heat source unit
for PWFY
Cooling capacity
(Nominal)
Power input
Current input
Temp. range of cooling
for outdoor unit
for heat source unit
for PWFY
Connectable
Total capacity
outdoor unit
Model / Quantity
/heat source unit
Sound pressure level (measured in anechoic room)
Diameter of
Liquid
refrigerant pipe
Gas
Inlet
Diameter of
water pipe
Outlet
Field drain pipe size
External finish
External dimension H × W × D
Net weight
Circulating water
Operation Volume
Range
R410a
Design pressure
Water
Drawing
External
Wiring
Standard attachment
Document
Accessory
Optional parts
Remark
Note:
*1 Nominal heating conditions (PWFY conditions are indicated in the parentheses.)
<Y/HP (ZUBADAN)/R2-series>
Outdoor temp. : 7°CDB/6°CWB (45°FDB / 43°FWB)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0 m (0 ft)
(Inlet water temp. 30°C
*2 Nominal cooling conditions (PWFY conditions are indicated in the parentheses.)
<Y/HP (ZUBADAN)/R2-series>
Outdoor temp. : 35°CDB (95°FDB)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0 m (0 ft)
(Inlet water temp. 23°C
* Due to continuing improvement, the above specifications may be subject to change without notice.
* The unit is not designed for outside installations.
* Please do not use the steel material for the water piping material.
* Please always make water circulate or add the brine to the circulation water when the ambient temperature becomes 0°C or less.
* Please always make water circulate or pull out the circulation water completely when not using it.
* Please do not use ground water and well water.
*1
kW
*1
kcal / h
*1
BTU / h
kW
A
W.B
W.B
W.B
-
-
-
*2
kW
*2
kcal / h
*2
BTU / h
kW
A
D.B
D.B
D.B
-
-
-
dB<A>
mm(in.)
mm(in.)
mm(in.)
mm(in.)
mm(in.)
mm
in.
kg(lbs)
m
/h
3
MPa
MPa
<WY/WR2-series>
Circulating water temp. : 20°C (68°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0 m (0 ft)
Water flow rate 4.30 m
/h)
(Inlet water temp. for PWFY side 30°C
3
<WY/WR2-series>
Circulating water temp. : 30°C (86°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0 m (0 ft)
Water flow rate 3.86 m
/h)
(Inlet water temp. for PWFY side 23°C
3
1-phase 220-230-240V 50/60Hz
-20~32°C (-4~90°F) R2-series
-20~15.5°C (-4~60°F) Y-series
-25~15.5°C (-13~60°F) HP(ZUBADAN)-series
10~45°C (50~113°F) WR2-series
10~45°C (50~113°F) WY-series
-5~46°C (23~115°F) R2-series
-5~46°C (23~115°F) Y-series
-5~43°C (23~110°F) HP(ZUBADAN)-series
10~45°C (50~113°F) WR2-series
10~45°C (50~113°F) WY-series
50~100% of outdoor unit/heat source unit capacity
PUHY-(E)P
PUHY-HP
PURY-(E)P
800 (785 without legs) × 450 × 300
31-1/2" (30-15/16" without legs) × 17-3/4" × 11-13/16"
Installation Manual, Instruction Book
Strainer, Connector, Heat insulation material, 2 × Connector sets, Expansion joint, wire, Flow switch × 1set
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and
other items shall be referred to the Installation Manual.
Water flow rate 4.30 m
Water flow rate 3.86 m
* Install the outdoor unit (R2-series) in an
environment where the wet bulb temp. will
not exceed 32°C.
* The water circuit must use the closed circuit.
* Please do not use it as a drinking water.
- 5 -
PWFY-P200VM-E1-AU
25.0
21,500
85,300
0.015
0.068 - 0.065 - 0.063
10~40°C (50~104°F)
22.4
19,300
76,400
0.015
0.068 - 0.065 - 0.063
10~35°C (50~95°F)
Y(S)JM-A(1)(-BS)
Y(S)HM-A(-BS)
PQHY-P
Y(S)HM-A
Y(S)JM-A(1)(-BS)
PQRY-P
Y(S)HM-A
29
ø9.52 (ø3/8") Brazed
ø19.05 (ø3/4") Brazed
PT 1 Screw
PT 1 Screw
ø32 (1-1/4'')
NO
33 (73)
1.8~4.30
4.15
1.00
WKB94L763
WKE94C230
NONE
Unit converter
kcal/h = kW × 860
×
BTU/h = kW
cfm
= m
/min × 35.31
3
lbs
= kg / 0.4536
/h)
3
* The specification data is subject
to rounding variation.
/h)
3
3,412